![Nielsen ID3 Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/nielsen/id3/id3_user-manual_1688186041.webp)
ID3 Tag Validator Application User Manual
Release 1.8 Revision F
40
Nielsen Confidential
Corresponding Log Message
If Validator determines that the PTS field is missing from the Nielsen ID3 DATA tag PES
header, it logs this error message:
-67: Missing PTS in Nielsen PES header.
Example
The example below shows that Validator found no PTS fields were missing from any
DATA-tag PES headers. The test passed because Validator allows up to 16 missing PTS
fields.
MPEG-2: Missing PES PTS Test: Pass <0/0/16>
Test 27 Result: PES Header Test
Format
Format
<number of PES-header errors / 0 / maximum
tolerated>
Number of Errors
Number of errors detected
0
Not used
Maximum Tolerated
Maximum number of errors tolerated before failure is declared
Meaning
Each Nielsen metadata PES packet header must have a stream ID of 0xBD and it must
include a non-zero PES packet size, as specified in the document “Timed Metadata for
HTTP Live Streaming.” See “Related Documents” on page 7.
Corresponding Log Message
If the PES packet stream ID is incorrectly set or if the PES packet size of a Nielsen ID3
PES packet is set to 0, one of the following error messages is logged:
-3: Warning: PES header not valid for ID3 Tag Metadata Packet
-3: Warning: PES packet length is set to 0!
Example
The example below shows Validator found no PES header errors. The test passed
because Validator allows up to five errors.
MPEG - 2 : PES Header Test: Pass <0/0/5>