Test 12 Result: INFO Tag Count
Format
Summary Report
Format
<count of INFO tags/ minimum required / 0>
Count
Number of INFO tags found in the stream
Minimum Required
Minimum number of INFO tags required
0
Not used
Periodic Report
Format
<number of seconds since last INFO tag / 0 /
maximum interval between tags>
Number of Seconds
Number of seconds since last INFO tag
0
Not used
Maximum Interval
Maximum allowable interval between INFO tags
Meaning
Summary Report
The INFO-tag check reports the number of INFO tags that occurred during the entire
length of processed content, as compared to the minimum number of INFO tags that
must be seen for the test to pass.
Periodic Reports
The INFO-tag test reports the number of seconds since the last INFO tag was detected in
the stream. If Validator has seen no INFO tags within the first 300 seconds of content, the
INFO-tag test reports the number of seconds since the start of content.
INFO tags are expected to arrive at 5-minute intervals. If 310 seconds expire without an
INFO tag, the INFO-tag check fails for that period.
Examples
Summary Report
In the example below, Validator found nine INFO tags in the stream. The test passed
because Validator requires a minimum of seven INFO tags.
ID3 Tag: INFO Tag Count: Pass <9/7/0>