C.2 Lighting Procedures
1. Broiler is
centered under
hood and
plugged in
2. Gas valve is
open when
handle is in line
(parallel to) the
pipe
3. Turn ventilation
system on
1
Turn the MAIN POWER SWITCH (a) on.
The MPB84 is equipped with automatic ignition. When the broiler is turned on, a hot surface ignitor turns on 5 seconds
before the flow of gas. Gas then flows to all of the burners. If the burners are not lit within 10 seconds, the control will
reset and try again for 10 seconds. This occurs 3 times. If the broiler does not light after the third attempt, the ignition
failure light will flash and the main on/off switch must be cycled to repeat the procedure. If this still doesn’t light the
broiler, see the MANUAL IGNITION instructions.
2
Check GAS PRESSURE GAUGE (a) reading.
Gauge should read 4.5” (for Natural Gas or 11” for
LP). If the gauge is not easy to see look to make
sure that all burners - upper and lower - have lit.
a
3
Allow broiler to heat for 45 minutes before cooking.
After warm-up period, the load sensing control
should read ‘Rdy’.
WARNING
THE VENTILATION SYSTEM MUST
BE ON AT ALL TIMES DURING
BROILER OPERATION. OPERATING
BROILER WITHOUT PROPER
VENTILATION IS A SEVERE FIRE
HAZARD.
NORMAL IGNITION
PRE-LIGHTING PREPARATION
a
Nieco Corporation - Model MPB84
Содержание MPB84
Страница 2: ......
Страница 27: ...27 Nieco Corporation Model MPB84 F PARTS LOCATION DRAWINGS MPB84 Feed End View...
Страница 28: ...28 Nieco Corporation Model MPB84 F PARTS LOCATION DRAWINGS MPB84 Discharge End View...
Страница 29: ...29 G WIRING DIAGRAM Left Side Nieco Corporation Model MPB84...
Страница 30: ...30 Nieco Corporation Model MPB84 G WIRING DIAGRAM Right Side...