6
<Non-Display[Temporary]Mode>
・When the keys are not operated for more than 10 seconds during Operation Mode, the system will automatically select Non-Display[Temporary]Mode and
the display will turn off.
・Decimal point LED shown in the figure below will blink during Non-Display[Temporary]Mode.
・Using the EEPROM, the PG-35L can retain preset values even if the power is turned off.
・If an error message is detected, the display will comeback and show the error message.
・You can change any functions during Non-Display[Temporary]Mode.
<Non-Display[Full-time]Mode>
・In Non-Display[Full-time]Mode, the display will be turned off and the Keys will be locked.
・Decimal point LED shown in the figure below will light up during Non-Display[Full-time]Mode.
・Using the EEPROM, the PG-35L can retain the preset values even if the power is turned off.
・If an error message is detected, the display will comeback and show the error message.
・You cannot change any functions during Non-Display[Full-time]Mode.
・To enable Non-Display[Temporary]Mode, press key for more than 4 seconds. will be displayed and Non-Display [Temporary]Mode will be set.
After 10 seconds, display will go off.
・To disable Non-Display[Temporary]Mode, press key for more than 4 seconds. will be displayed and Non-Display [Temporary]Mode will be canceled.
(How to set)
■
Non-Display Mode
kPa
+/−
SW1
SW2
C O PA L E L E C T R O N I C S
kPa
+/−
SW1
SW2
C O PA L E L E C T R O N I C S
kPa
+/−
SW1
SW2
C O PA L E L E C T R O N I C S
kPa
+/−
SW1
SW2
C O PA L E L E C T R O N I C S
・To enable Non-Display[Full-time]Mode, press key for more than 4 seconds. will be displayed and Non-Display [Full-time]Mode will be set.
Display will turn off in a second.
・To disable Non-Display[Full-time]Mode, press key for more than 4 seconds. will be displayed and Non-Display [Full-time]Mode will be canceled.
(How to set)
kPa
+/−
SW1
SW2
C O PA L E L E C T R O N I C S
kPa
+/−
SW1
SW2
C O PA L E L E C T R O N I C S
kPa
+/−
SW1
SW2
C O PA L E L E C T R O N I C S
kPa
+/−
SW1
SW2
C O PA L E L E C T R O N I C S
Blink
Light up
・To enable Key Protection Mode, press key for more than 4 seconds. will be displayed and the keys will be locked.
・To disable Key Protection Mode, press key for more than 4 seconds. will be displayed and the keys will be unlocked.
<Key Protection Mode>
・Key Protection Mode is used to lock the front panel key in order to prevent preset values from being accidentally changed.
・Using EEPROM, the PG-35L can retain the preset values even if the power is turned off.
■
Key Protection Mode
(How to set)
kPa
+/−
SW1
SW2
C O PA L E L E C T R O N I C S
kPa
+/−
SW1
SW2
C O PA L E L E C T R O N I C S
kPa
+/−
SW1
SW2
C O PA L E L E C T R O N I C S
Outline Dimensions(Unit : mm)
■PG-35L Outline Dimensions
16
16
□30
(68.7)
(M5 screws included)
L=2000±100
COPAL ELECTRONICS
31.4
Five core shilded cable
kPa
Air intake
2-M4 Depth5
R1/4(PT1/4)
10.5
(32)
Fitting part:R2 type
37