5
Troubleshooting
Zero point Adjustment
Others
Press the and buttons.
Press the button until
all LED do not flashe.
Set the value to “F-3”
using the and
buttons.
Press the button for
more than one second to
return to the Operations
Mode.
■If the following error messages are displayed, follow the procedures in the table.
Display and problem
Cause
Solution
E-1
E-2
E-3
,
E-4
999
Flashing
Flashing of the pressure value
Black out of the display
Disable the key operation
Output current is exceeding 100mA.
Turn off the power and verify the load
connected switch output 1 and 2.
Press M button and return the applied pressure to the
atmospheric pressure and try zero-point adjustment again.
Please contact us. Please use a regulated DC power
supply and measures for the power line noise.
Normal state
Normal state
Normal state(See Non-display mode.)
Normal state(See Key protection mode.)
Pressure was applied at the zero point
adjustment.
Failure of the internal circuit.
Pressure values exceed the display range.
Pressure values exceed the rated pressure
range.(110%FS)
Non-display mode
Key protection mode
If there is any possibility that the sensor may become wet with oil or water, which may
enter the case through the air intake, connect a silicon tube, or similar, to the intake
and position the end of the tube in a suitably safe place. Be sure not to bend the tube
or block the end of the tube.
Note:20digits is set prior to delivery.
An example of setting a hysteresis value of 8.0kPa with the 102R(kPa).
Example of a tube with
external diameter of φ4
and internal diameter
of φ2.5
■
Hysteresis setting
■
Digital Filter setting
■
Tube at atmospheric pressure intake
To set hysteresis the
“−”
LED should be flashing.
To set Digital Filter all LED should be not flashing. An example of setting 2.5s response time by Digital Filter.
Press the and buttons.
Press the button until
the −LED flashes.
Set the value to “8.0”
using the and
buttons.
Press the button for
more than one second to
return to the Operations
Mode.
Note:“F-0”is set prior to delivery.
kPa
+/−
SW1
SW2
C O PA L E L E C T R O N I C S
Use a wrench on a hexagon of fitting part. Do not hold the main body when tightening.
■
Piping
Pressing the and buttons simultaneously in the Operations Mode
displays on the screen. One second later this change to than
the and buttons are released.(If the pressure port is opened to
the atmosphere.)
Note:You have to adjust Zero under open air condition.
Otherwise you can be seen E‐2 error as you adjusted Zero with residual pressure.