manualshive.com logo in svg
background image

5077     - 2017.12 / b

Powerdrive MD2SL

Installation and maintenance

en

Reference :

180T to 1700T

340TH à 1800TH

Liquid-cooled freestandring

variable speed drive

Содержание Leroy Somer Powerdrive MD2SL 1100T

Страница 1: ...5077 2017 12 b Powerdrive MD2SL Installation and maintenance en Reference 180T to 1700T 340TH 1800TH Liquid cooled freestandring variable speed drive...

Страница 2: ...l that the user takes appropriate precautions against the motor restarting after an unscheduled stop The variable speed drive is designed to be able to supply a motor and the driven machine above its...

Страница 3: ...in the documentation supplied with the product The variable speed drives must be protected against any excessive stress In particular there must be no damage to parts and or modification of the clear...

Страница 4: ...oc Sortie axiale Engrenages h lico daux Orthobloc Sortie orthogonale Engrenages h lico daux et couple conique Ventilation forc e radiale Moteur IMfinity LSES FLSES Moteur LSMV Moteur Dyneo PLSRPM LSRP...

Страница 5: ...minal blocks 22 3 1 5 Cables and fuses 22 3 2 Connection of the control 24 3 2 1 Control terminal block location 24 3 2 2 Control terminal block characteristics 24 3 2 3 Factory configuration of contr...

Страница 6: ...feedback options 34 5 2 3 Additionnal I O options 34 5 3 Electrical protections 35 5 3 1 aR semi conductor fuses 35 5 3 2 Line switch 35 5 3 3 Emergency stop 35 5 4 Heater kit 35 5 5 RFI filters 35 6...

Страница 7: ...nding installation manual Nameplate ENTREE INPUT Ph V V Hz Hz I A 3 400 480 50 60 295 TYPE S N 09999999999 MADE IN FRANCE Powerdrive MD2SL 180T Alim auxiliaire 200VA I A maximum input current for 400...

Страница 8: ...seconds Heavy duty For heavy duty constant torque machines presses grinders hoisting etc and all applications where significant inertia has to be accelerated quickly centrifuges translation of travel...

Страница 9: ...600 615 700 700 780 860 900TH 700 700 720 850 900 940 1010 1200TH 850 900 900 1100 1000 1090 1260 1500TH 1100 1000 1075 1300 1250 1410 1510 1800TH 1300 1250 1355 1600 1500 1630 1900 1 Motor winding vo...

Страница 10: ...540 540 540 510 540 540 540 540 540 Normal duty 650 650 630 620 580 650 650 640 630 620 470T Heavy duty 670 670 645 580 670 670 660 615 Normal duty 800 800 735 660 800 800 750 700 570T Heavy duty 750...

Страница 11: ...duty 580 580 560 500 460 580 580 580 540 485 750TH Heavy duty 615 615 615 610 540 615 615 615 615 610 Normal duty 780 780 780 700 620 780 780 780 750 700 900TH Heavy duty 720 720 720 720 710 720 720...

Страница 12: ...all a heating system Prevent access by unauthorised personnel 2 1 Checks upon receipt Make sure that the cabinet has been transported vertically as otherwise it could be damaged Before installing the...

Страница 13: ...vy duty 7 6 8 0 8 9 Normal duty 9 4 9 9 11 0 500TH Heavy duty 8 9 9 3 10 3 Normal duty 11 4 12 0 13 3 600TH Heavy duty 11 1 11 7 12 9 Normal duty 13 2 13 9 14 9 Rating Duty Losses kW 2kHz 3kHz 4kHz 75...

Страница 14: ...ve is disable during more than 1 minute Coolant minimum temperature Internal air temperature of the Powerdrive MD2SL cabinet C 1 bar 10 C 15 C 20 C 25 C 30 C 35 C 40 C 45 C 50 C Relative Humidity 40 2...

Страница 15: ...speed up obstruction of the heatsinks due to sediment and it is therefore advisable to install filters upstream of the drive fluid system 2 3 3 4 Draining and servicing The frequency of the draining a...

Страница 16: ...ce 5077 2017 12 b en Heatsinks User connection for cooling circuit inlet User connection for cooling circuit outlet Vertical ramp protective plate Knurled nut Water system drain valve Drainage dischar...

Страница 17: ...on the cooling unit To make it easier to drain the cooling circuit it is advisable to use a by pass valve in the main pipe and valves on each cabinet inlet The installation of a sensor for detecting...

Страница 18: ...ions can be fitted into the Powerdrive MD2SL without affecting its dimensions MD AU1 emergency stop Communication modules Additional I O modules Speed feedback modules The table below gives the produc...

Страница 19: ...ening torque 180T to 270T 340T to 1700T 340TH to 1800TH Mains power supply L1 L2 L3 or R S T See 3 1 4 M10 screw bolt 20 Nm 15 lb ft Motor outputs U V W See 3 1 4 Earth PE See 3 1 4 M10 bolt 20 Nm 15...

Страница 20: ...SL 340T MD2SL 400T MD2SL 470T MD2SL 570T MD2SL 340TH MD2SL 400TH MD2SL 500TH with options 55 100 BR1 BR2 U V W L1L2L3 PE PE 220 50 50 50 60 60 60 60 60 60 60 MD2SL 180T MD2SL 220T MD2SL 270T without o...

Страница 21: ...50T MD2SL 900T MD2SL 1100T MD2SL 750TH MD2SL 900TH MD2SL 1200TH with option U V W PE BR1 BR2 PE 55 75 75 50 50 50 75 75 120 75 75 55 220 50 100 93 50 50 75 75 120 75 75 50 75 75 50 L1 L2 L3 MD2SL 1500...

Страница 22: ...370 400 630 3x240 PE 365 400 630 500 3x240 PE 400 3x240 PE 270T Heavy 370 400 630 3x240 PE 365 400 630 600 3x240 PE 375 3x240 PE Normal 460 500 800 2x 3x150 PE 425 500 700 600 2x 3x120 PE 470 2x 3x150...

Страница 23: ...00TH Heavy 1350 1250 3x550 1355 Normal 1665 1600 3x630 1630 Note The line current value IL is a typical value which depends on the source impedance The higher the impedance the lower the current 1 gG...

Страница 24: ...2 2 1 PX1 terminal block characteristics 1 10V 10 V internal analog source Accuracy 2 Maximum output current 10 mA 2 AI1 Differential analog input 1 3 AI1 Differential analog input 1 Factory setting...

Страница 25: ...mended fuse 2 5 A An external power supply connected to the 24V Ref terminal is used to maintain the control power supply in the event of mains loss 2 DO1 Digital output Factory setting Zero speed Cha...

Страница 26: ...ith factory settings default parameter settings The STO 1 and STO 2 inputs must be closed before giving a run command If the motor thermal sensor needs to be connected to DI1 PTC set Mtr 06 05 70 Driv...

Страница 27: ...be adhered to The STO 1 STO 2 inputs are safety components which must be incorporated in the complete system dedicated to machine safety As for any installation the complete machine must be subject t...

Страница 28: ...device is defined by its ability to operate in an environment which is contaminated by external elements or by its electrical connections 4 2 2 Standards Each device must undergo a series of standard...

Страница 29: ...ches do not excessively distort the mains voltage and do not create voltage peaks with amplitude higher than 2 x mains Vrms If this is the case it is essential to take corrective measures by inserting...

Страница 30: ...ors for protective earthing as indicated below The shield must be connected at both ends drive end and motor end connected round the whole circumference U W V PE PE PE Shielding A separate PE protecti...

Страница 31: ...1000 4 3 Immunity standards for radiated radio frequency Product casing Level 3 industrial EN 61000 4 3 IEC 61000 4 4 Bursts of fast transients Control cable Level 4 industrially hardened EN 61000 4 4...

Страница 32: ...ower supply F Touch sensitive buttons for language selection can take a few minutes to load 5 PARAMETER SETTING INTERFACE AND OPTIONS 5 1 Parameter setting interfaces 5 1 1 Location of the drive conne...

Страница 33: ...ation Trip history Gives a quick overview of the last 10 drive trips This button is accessible on all screens in factory set configuration and is used to give a stop command can be disabled At any tim...

Страница 34: ...werdrive MD2SL MDX CM MODBUS Modbus RTU RS485 232 MDX CM ETHERNET Modbus TCP Ethernet MDX CM ETHERNET IP EtherNet IP MDX CM PROFIBUS Profibus DP V1 MDX CM PROFINET ProfiNet For more details consult th...

Страница 35: ...rdrive MD2SL rating Switch Reference Ith 400V A Ith 690V A Number of operations 180T 220T QS3P_400A 400 400 5 000 270TH 340TH 270T 340T QS3P_630A 630 630 5 000 400TH to 600TH 400T QS3P_800A 800 800 3...

Страница 36: ...numbered higher than 100 only the last 2 digits are displayed with a point displayed on both LEDs to indicate the hundred Example indicates trip no 1 indicates trip no 101 After consulting the table...

Страница 37: ...Clean the cabinet dust filters Check the drive external and internal fans are working correctly Check that the product air inlet temperature is not outside the limits 11 Encoder rot The measured posi...

Страница 38: ...onnection of the fieldbus during operation or timing error Check the fieldbus connections Check that parameter 15 07 is compatible with the timing of requests from the master 35 STO inputs Simultaneou...

Страница 39: ...the motor current level 59 IGBT W overheating Overheating of phase W IGBTs 60 Diagnostic Problem detected during the control and interface boards test the power test or during the self test Check that...

Страница 40: ...the motor switch off the drive and disconnect the motor There are very few maintenance and repair operations to be performed by the user on Powerdrive MD2SL drives Regular servicing operations are des...

Страница 41: ...180T to 570T ratings 270TH to 500TH PEF720NG000 5 Rating indentification Board Consult LS 7 Interface board 60T to 270T PEF400NE001A Interface board 340T to 570T PEF400NE003A Interface board 270TH to...

Страница 42: ...L Protection fuses for the transformer primary Rating Fuse Size Type Value T F7 10 x 38 aM ATQ 4A 500V F8 TH F7 10 x 38 aM 4A 690V F8 Motor output bar fuse Board reference Ratings 340T to 1400T PEF240...

Страница 43: ...43 1 2 6 10 31 40 25 27 MAINTENANCE Powerdrive MD2SL Installation and maintenance 5077 2017 12 b en...

Страница 44: ...Moteurs Leroy Somer Headquarter Boulevard Marcellin Leroy CS 10015 16915 ANGOUL ME Cedex 9 Limited company with capital of 65 800 512 RCS Angoul me 338 567 258 www leroy somer com IMP297NO 667...

Отзывы: