![NICOR VT2 LED VAPORTITE Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/nicor/vt2-led-vaportite/vt2-led-vaportite_installation-instructions_1687717002.webp)
NICOR, Inc. 2200 Midtown Place NE, Albuquerque, NM 87107 P: 800.821.6283 F: 800.892.8393 www.nicorlighting.com
April 12
, 201
8
11:25A
M VT2-20 rev 1.
1
Page 2 of 4
If using a motion sensor (sold separately), remove
bottom plug and install desired sensor (hole is 1/2”
KO through hole).
Wire cord to fixture as shown. If using motion
sensor, wire according to sensor wiring diagram.
For condensation valve use (recommended in
certain enviroments): remove top plug from
opposite end of power input and insert
Condensation Valve (sold separately) (hole is
threaded 1/2” NPT)
Reattach endcap to fixture ensuring cap seats
fully on gasket and tighten cord grip fully.
Remove endcap bolts and endcap using M3
hex/allen wrench.
Pull cord through cord grip at least 6”. 5-wire cord
is required if dimming is desired
Remove top plug from fixture end and insert
Cord Grip (hole is threaded 1/2” NPT).
Push up luminaire and press it into mounting
brackets until fixture snaps into place.
6
10
7
11
4
8
5
9
INSTALLATION WITH CORD
(using included Cord Grip)
NOTE:
Use of condensation valve prevents through wiring/continuous run.
NOTE:
Fixture is pre-wired for through wiring.
ATTENTION:
Order of installation for continuous run is as follows:
1) Follow steps 4-10 above, step 9 was completed previously. Do not tighten the cord grip to wiring until end cap is fully re-installed.
2) Slide endcap along wiring until in position on mounted fixture
3) Follow step 11 above to finalize installation
CAUTION: For continuous runs the maximum number of fixtures is as follows: 2ft = 40, 4ft = 20
6” Typ
.
Com
Line
1 - 10V (-)
1 - 10V (+)
Luminaire
Purple
Gray
GND
White
Black
GND