NiCom RSL900 Скачать руководство пользователя страница 8

When inserting or removing printed circuit boards (PCBs), cable connectors, or
fuses, always turn off power to the affected portion of the equipment. After power is
removed, allow sufficient time for the power supplies to bleed down before
reinserting PCBs.

When troubleshooting, remember that FETs and other metal-oxide semiconductor
(MOS) devices may appear defective because of leakage between traces or
component leads on the printed circuit board. Clean the printed circuit board and
recheck the MOS device before assuming it is defective.

When replacing MOS devices, follow standard practices to avoid damage caused
by static charges and soldering.

When removing components from PCBs (particularly ICs), use care to avoid
damaging PCB traces.

PROCEDURE TO ESTABLISH THE ABSENCE OF VOLTAGE 

Follow these simple steps for establish the absence of voltage: 

Before starting work on the equipment, it shall be isolated from the main power
supply. This disconnection shall always be checked by visual inspection. Further
precautions shall be taken to ensure that the main supply cannot be restored while
work is being carried out. After the main supply has been disconnected, all other
lines such as the control, interlocking and modulation lines shall be disconnected if
they carry dangerous voltage. Moreover, the antenna or the antenna transmission
line shall be disconnected from the antenna terminal device to prevent the
introduction of dangerous voltage due to antenna pick-up. When disconnection of
the antenna or antenna transmission line is not possible, other suitable precautions
shall be taken, for example, earthing, when necessary at several places, to
establish absence of voltage. These earthing connections shall be very short
compared with the wave-length.

Capacitors,  which are connected to a circuit isolated from its supply, shall be
discharged (and have their terminals permanently short-circuited, and the casing
earthed) during the whole period of the work.

The electrical charge retained by electrical machinery when stopped may, in certain
cases, be sufficient to cause a severe shock. This shall be taken into account when
making connections to an apparently "dead" machine. Therefore, all machinery
shall be discharged and earthed using an adequately insulated lead for this
purpose. The discharge operation shall be repeated several times.

Содержание RSL900

Страница 1: ...TSL910 RSL900 STL SYSTEM OPERATOR AND SERVICE MANUAL...

Страница 2: ......

Страница 3: ...ice There are many devices on the market that protect the AC line and they are all useful surge suppressors stabilizers etc However only one is really mandatory to avoid disasters caused by the AC It...

Страница 4: ...le feeding the transmitter install a pigtail with proper power capability and more flexibility so that you do not put too much pressure on the connector Before proceeding to operate we strongly recomm...

Страница 5: ...the internal checks and lock onto the frequency After that it will start delivering power 4 Always start with low power and keep an eye on the reading of the reflected power to be sure that your syst...

Страница 6: ...ltages Do not assume that all danger of electrical shock is removed when the power is off Charged capacitors can retain dangerous voltages for long periods of time after the power is turned off These...

Страница 7: ...osive atmosphere To avoid personal injury do not remove the product covers or panels Do not operate the product without the covers and panels properly installed GOOD PRACTICE In maintaining the equipm...

Страница 8: ...not be restored while work is being carried out After the main supply has been disconnected all other lines such as the control interlocking and modulation lines shall be disconnected if they carry da...

Страница 9: ...level of 240 VA or more at a potential of 2 V or more Precautions for Handling Components Containing Toxic Material The Beryllium Beryllium Oxide is used in the construction of some components of the...

Страница 10: ...operations The tag of CAUTION is used for the majority of electronic devices that are subject to electrical shocks If electronic parts have to be touched during installation or repair please observe...

Страница 11: ...ound the victim and pull him free of the power Carefully avoid touching him or his clothing until free of power DO NOT TOUCH VICTIM OR HIS CLOTHING BEFORE POWER IS DISCONNECTED OR YOU CAN ALSO BECOME...

Страница 12: ...im according to the type of accident Arrange transportation to a hospital as quickly as possible If arms or legs are affected keep them elevated If medical help is not available within an hour and the...

Страница 13: ...PLL LOCK led will light and the Display will show an increasing bar after a further 5 seconds the green ON AIR LED will light and the unit will start increasing power Once the unit has finished the cy...

Страница 14: ...r move the underscore character position at the default digit and press the SET key to confirm the digit Carry out the same operation for the two remaining digits If the password is corrected press SE...

Страница 15: ...e same method for the default password The confirmation password will be required If the password is corrected the display will show CONFIRM Y N N SEL Y SET SELECT SELECT SELECT SELECT SET SET SET SET...

Страница 16: ...ss 3 seconds the SELECT key and put the correct password at this point press again the SELECT key Press the SELECT key to change the digit and press the SET key to confirm the digit The underscore cha...

Страница 17: ...is operation it will follow the WAIT cycle and then the display will show the parameters After 7 minutes the display light will switch off and the display will show MOD FRW 8 0W RFL 0 0W SELECT SELECT...

Страница 18: ...m of the output power of the apparatus to guarantee the limits of exposure declared within this document it is necessary that the antenna gain used with this device should be 0dBi or less and all pers...

Страница 19: ...ributor if unit was purchased through them and if your dealer is not able to assist you then contact Nicom directly or through our website to fill out a return authorization form to obtain a return au...

Отзывы: