 INSTALLATION 

The installation of any electrical equipment should be  made by trained 
technicians who know the risks related to handling electrical supplies. 
Before proceeding with  the installation, it is necessary to verify that the 
equipment is in compliance with the rules of the Country where the unit will 
operate. Before connecting the transmitter to the AC source, it is necessary to 
verify that the voltage range reported in the  back of the unit matches the 
voltage of the AC supplied. Here are some important details about electrical 
systems. 

 ELECTRICAL SYSTEM 

Depending upon the exact location of the site, electricity is subject to more or 
less fluctuations in power. Fluctuation in voltage is not the only issue you can 
have with electricity.  Most  of the time,  you can have spikes and peaks  of 
power that last for very short  intervals  but that are sufficient to destroy your 
device. There are many devices on the market that protect the AC line and 
they are all useful (surge suppressors, stabilizers etc.). However, only one is 
really mandatory to avoid disasters caused  by the AC. It is called  an 
ISOLATION TRASFORMER.  The isolation transformer creates  a physical 
separation from the input of your AC line to the trasmitter. Anything 
destructive  that  would come through  the AC,  stops in the transformer and 
cannot reach the transmitter. 

This device is indispensable  because,  in the last 10 years,  the  broadcast 
industry has developed new smaller power supplies that are very light.  They 
did this to allow the units to be lighter for easy trasportation. Unfortunately, 
the  side  the downside is that the big transformers that were located inside 
the units protecting them,  have been removed. The new AC-DC power 
supplies do not give any sort of protection. The isolation transformer is 
necessary to give that protection. A big isolation transformer installed where 
the AC enters  the  site  protect not only one  specific device, but all of  the 
equipment that are in the same building. 

 

Содержание RSL900

Страница 1: ...TSL910 RSL900 STL SYSTEM OPERATOR AND SERVICE MANUAL...

Страница 2: ......

Страница 3: ...ice There are many devices on the market that protect the AC line and they are all useful surge suppressors stabilizers etc However only one is really mandatory to avoid disasters caused by the AC It...

Страница 4: ...le feeding the transmitter install a pigtail with proper power capability and more flexibility so that you do not put too much pressure on the connector Before proceeding to operate we strongly recomm...

Страница 5: ...the internal checks and lock onto the frequency After that it will start delivering power 4 Always start with low power and keep an eye on the reading of the reflected power to be sure that your syst...

Страница 6: ...ltages Do not assume that all danger of electrical shock is removed when the power is off Charged capacitors can retain dangerous voltages for long periods of time after the power is turned off These...

Страница 7: ...osive atmosphere To avoid personal injury do not remove the product covers or panels Do not operate the product without the covers and panels properly installed GOOD PRACTICE In maintaining the equipm...

Страница 8: ...not be restored while work is being carried out After the main supply has been disconnected all other lines such as the control interlocking and modulation lines shall be disconnected if they carry da...

Страница 9: ...level of 240 VA or more at a potential of 2 V or more Precautions for Handling Components Containing Toxic Material The Beryllium Beryllium Oxide is used in the construction of some components of the...

Страница 10: ...operations The tag of CAUTION is used for the majority of electronic devices that are subject to electrical shocks If electronic parts have to be touched during installation or repair please observe...

Страница 11: ...ound the victim and pull him free of the power Carefully avoid touching him or his clothing until free of power DO NOT TOUCH VICTIM OR HIS CLOTHING BEFORE POWER IS DISCONNECTED OR YOU CAN ALSO BECOME...

Страница 12: ...im according to the type of accident Arrange transportation to a hospital as quickly as possible If arms or legs are affected keep them elevated If medical help is not available within an hour and the...

Страница 13: ...PLL LOCK led will light and the Display will show an increasing bar after a further 5 seconds the green ON AIR LED will light and the unit will start increasing power Once the unit has finished the cy...

Страница 14: ...r move the underscore character position at the default digit and press the SET key to confirm the digit Carry out the same operation for the two remaining digits If the password is corrected press SE...

Страница 15: ...e same method for the default password The confirmation password will be required If the password is corrected the display will show CONFIRM Y N N SEL Y SET SELECT SELECT SELECT SELECT SET SET SET SET...

Страница 16: ...ss 3 seconds the SELECT key and put the correct password at this point press again the SELECT key Press the SELECT key to change the digit and press the SET key to confirm the digit The underscore cha...

Страница 17: ...is operation it will follow the WAIT cycle and then the display will show the parameters After 7 minutes the display light will switch off and the display will show MOD FRW 8 0W RFL 0 0W SELECT SELECT...

Страница 18: ...m of the output power of the apparatus to guarantee the limits of exposure declared within this document it is necessary that the antenna gain used with this device should be 0dBi or less and all pers...

Страница 19: ...ributor if unit was purchased through them and if your dealer is not able to assist you then contact Nicom directly or through our website to fill out a return authorization form to obtain a return au...

Отзывы: