NiCom RSL900 Скачать руководство пользователя страница 7

GENERAL INFORMATION FOR SAFETY

 

When connecting the equipment to power, please follow these important 
recommendations: 

This product is intended to operate from a power source that will not apply more
than 10% of the voltage specified on the rear panel between the supply conductors
or between either supply conductor and ground. A protective- ground connection by
way of the grounding conductor in the power cord is essential for safe operation.

This equipment is grounded through the grounding conductor of the power cord. To
avoid electrical shock, plug the power cord into a properly wired socket before
connecting to the product input or output terminals.

Upon loss of the protective-ground connection, all accessible conductive parts
(including parts that

may appear to be insulating) can render an electric shock.

To avoid fire hazard, use only the fuse of correct type, voltage rating, and current
rating. Refer fuse

replacement to qualified service personnel.

To avoid explosion, do not operate this equipment in an explosive atmosphere.

To avoid personal injury, do not remove the product covers or panels. Do not
operate the product without the covers and panels properly installed.

GOOD PRACTICE 

In maintaining the equipment covered in this manual, please keep in mind the following 
standards for good safety practice: 

At regular intervals, the condition of the equipment and the correct functioning of
protective and safety devices shall be checked by a skilled person approved by the
appropriate authority for this duty. Functional checks shall be carried out on
interlocking systems of doors, mechanical interlocks, isolating switches, earthing
switches, parallel resistances and protective devices against overvoltage and over-
currents. The above checks shall not be carried out after the protective and safety
devices have operated under faulty conditions. The safety devices shall not be
altered or disconnected except for replacement, nor shall the safety circuit be
modified without specific approval of the appropriate authority in each case.

When connecting any instrument (wattmeter, spectrum analyzer, etc.) to a high
frequency output, use the appropriate attenuator or dummy load to protect the final
amplifiers and the instrument input.

Содержание RSL900

Страница 1: ...TSL910 RSL900 STL SYSTEM OPERATOR AND SERVICE MANUAL...

Страница 2: ......

Страница 3: ...ice There are many devices on the market that protect the AC line and they are all useful surge suppressors stabilizers etc However only one is really mandatory to avoid disasters caused by the AC It...

Страница 4: ...le feeding the transmitter install a pigtail with proper power capability and more flexibility so that you do not put too much pressure on the connector Before proceeding to operate we strongly recomm...

Страница 5: ...the internal checks and lock onto the frequency After that it will start delivering power 4 Always start with low power and keep an eye on the reading of the reflected power to be sure that your syst...

Страница 6: ...ltages Do not assume that all danger of electrical shock is removed when the power is off Charged capacitors can retain dangerous voltages for long periods of time after the power is turned off These...

Страница 7: ...osive atmosphere To avoid personal injury do not remove the product covers or panels Do not operate the product without the covers and panels properly installed GOOD PRACTICE In maintaining the equipm...

Страница 8: ...not be restored while work is being carried out After the main supply has been disconnected all other lines such as the control interlocking and modulation lines shall be disconnected if they carry da...

Страница 9: ...level of 240 VA or more at a potential of 2 V or more Precautions for Handling Components Containing Toxic Material The Beryllium Beryllium Oxide is used in the construction of some components of the...

Страница 10: ...operations The tag of CAUTION is used for the majority of electronic devices that are subject to electrical shocks If electronic parts have to be touched during installation or repair please observe...

Страница 11: ...ound the victim and pull him free of the power Carefully avoid touching him or his clothing until free of power DO NOT TOUCH VICTIM OR HIS CLOTHING BEFORE POWER IS DISCONNECTED OR YOU CAN ALSO BECOME...

Страница 12: ...im according to the type of accident Arrange transportation to a hospital as quickly as possible If arms or legs are affected keep them elevated If medical help is not available within an hour and the...

Страница 13: ...PLL LOCK led will light and the Display will show an increasing bar after a further 5 seconds the green ON AIR LED will light and the unit will start increasing power Once the unit has finished the cy...

Страница 14: ...r move the underscore character position at the default digit and press the SET key to confirm the digit Carry out the same operation for the two remaining digits If the password is corrected press SE...

Страница 15: ...e same method for the default password The confirmation password will be required If the password is corrected the display will show CONFIRM Y N N SEL Y SET SELECT SELECT SELECT SELECT SET SET SET SET...

Страница 16: ...ss 3 seconds the SELECT key and put the correct password at this point press again the SELECT key Press the SELECT key to change the digit and press the SET key to confirm the digit The underscore cha...

Страница 17: ...is operation it will follow the WAIT cycle and then the display will show the parameters After 7 minutes the display light will switch off and the display will show MOD FRW 8 0W RFL 0 0W SELECT SELECT...

Страница 18: ...m of the output power of the apparatus to guarantee the limits of exposure declared within this document it is necessary that the antenna gain used with this device should be 0dBi or less and all pers...

Страница 19: ...ributor if unit was purchased through them and if your dealer is not able to assist you then contact Nicom directly or through our website to fill out a return authorization form to obtain a return au...

Отзывы: