background image

DMX 512 Configuration 

 

 

 

 

 

 
 
 

 
 
 
 

 
 
 
 

 
 
 

 
 

 
 

 
 

DMX512connections 

  

 

 

                                                     

1.

 

If you using a controller with 5 pins DMX output, you need to use a 5 to 3 pin adapter-cable. 

2.

 

At last unit, the DMX cable has to be terminated with a terminator. Solder a 120 ohm 1/4W resistor between pin 

2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it in the DMX-output of the last unit. 

3.

 

Connect the unit together in a `daisy chain` by XLR plug from the output of the unit to the input of the next unit. 

The cable can not branched or split to a `Y` cable. DMX 512 is a very high-speed signal. Inadequate or damaged 

cables, soldered joints or corroded connectors can easily distort the signal and shut down the system. 

Channel 

Function 

Value 

Description 

Dimmer 

0-255 

0-255 

Red 

0-255 

0-255

 

Green 

0-255 

0-255 

Blue 

0-255 

0-255 

White 

0-255 

0-255 

Dimming speed 

0-255 

Dimming  speed  from  fast  to 
slow 

Strobe 

0-255 

Strobe effect from slow to fast 

Auto Mode 

0-99 

Color macro 

100-119 

3 colors change 

120-139 

7 colors change 

140-159 

7 colors change smoothly 

160-179 

Colors fade strobe 

180-199 

7 colors strobe 1 

200-219 

7 colors strobe 2 

220-240 

Color jump change 

241-255 

No function 

Auto Speed 

0-255 

Auto speed from slow to fast 

Содержание PARLED 1412 FC IP

Страница 1: ...PARLED 1412 FC IP NOTICE D UTILISATION...

Страница 2: ...t La temp rature du boitier peut atteindre 60 C Ne jamais toucher l appareil mains nues pendant son fonctionnement Attendez 15 minutes avant de remplacer la lampe ou d effectuer toute autre r paration...

Страница 3: ...0 60 Hz Puissance 140W Canaux DMX 9 Mode de pilotage Auto DMX Master Slave Dimmer 0 100 Strobe 0 20Hz Angle 35 Indice IP 65 Dimensions 245 x 205 x 245 mm Poids 4 8kg REGLAGE DE L APPAREIL L cran affic...

Страница 4: ...AFFICHAGE MENUS...

Страница 5: ...s DMX 512 Canal Fonction Valeur Description 1 Dimmer 0 255 0 255 2 Red 0 255 0 255 3 Green 0 255 0 255 4 Blue 0 255 0 255 5 White 0 255 0 255 6 Dimming speed 0 255 R glage luminosit 100 0 7 Strobe 0 2...

Страница 6: ...ble ne doit pas tre branch un c ble en Y Des c bles inappropri s ou endommag s des joints soud s ou des connecteurs rouill s peuvent facilement tre l origine de la d formation du signal et couper le...

Страница 7: ...ez les connecteurs ou la carte lectronique de l appareil d faillant ainsi que de l appareil pr c dent 4 Essayer d utiliser un autre contr leur DMX 5 V rifiez l absence d interf rences entre les c bles...

Страница 8: ...PARLED 1412 FC IP User guide...

Страница 9: ...0 DO NOT operate it when the temperature is higher DO NOT connect the device to any dimmer pack During initial start up some smoke or smell may arise This is a normal process and does not necessarily...

Страница 10: ...e Hot lamp explosion hazard Do not open the unit within 15 minutes after switching off DO replace the bulb once it is damaged deformed or life expired DO NOT look directly at the light while the bulb...

Страница 11: ...functions Button MENU Menu selection or return to previous menu ENTER Confirm and quit out current function setting UP To go through the menu list to increase change the value of the current function...

Страница 12: ......

Страница 13: ...a Y cable DMX 512 is a very high speed signal Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system Channel Function Value Descrip...

Страница 14: ...fan does not work 1 Check the connection of power and main fuse 2 Measure the mains voltage on the main connector B Not responding to DMX controller 1 DMX LED should be on If not check DMX connectors...