background image

 

7- 

installation, operation and maintenance. 

Please keep this User Manual for future consultation. If you sell the unit to another user, be 

sure that they also receive this instruction booklet. 

Unpack and check carefully there is no transportation damage before using the unit. 

Before operating, ensure that the voltage and frequency of power supply match the power 

requirements of the unit.   

It‟s important to ground the yellow/green conductor to earth in order to avoid electric shock. 

The unit is for indoor and outdoor use. 

The  unit  must  be  installed  in  a  location  with  adequate  ventilation,  at  least  50cm  from 

adjacent surfaces. Be sure that no ventilation slots are blocked.   

Disconnect mains power before fuse replacement or servicing.   

Make  sure  there  are  not  flammable  materials close  to  the unit  while  operating  as  it  is  fire 

hazard.   

Use safety cable when fixes this unit. 

Maximum ambient temperature is 40°C and don‟t operate it where the temperature is higher 

than this. 

There are no user serviceable parts inside the fixture. Do not open the housing or attempt 

any repairs by yourself. In the unlikely event your fixture may require service, please contact 

the  nearest  authorized  technical  assistance  center  and  always  use  the  same  type  spare 

parts.     

The housing must be replaced if they are visibly damaged. 

Do not touch any wire during operation as high voltage may cause electric shock. 

Do not look directly at the LED light beam while the fixture is on. 

Do not look at the beam light directly to avoid any visual problems. 

Possibly hazardous optical radiation emitted from this product. 

 

2. Technical specifications 

Weight: 3.8kg       

Size: 11.4 x 12 x 12 cm 

Power input: AC230V/50 HZ

 

Wattage: 60W 

 

LEDS: 12*tri-3W LEDs 

Beam angle: 40 degree 

IP rate: IP65

 

Содержание LED BAR 123 FC IP

Страница 1: ...LED BAR 123 FC IP Manuel d utilisation Nouvelle technologie LED Nous vous recommandons de lire attentivement le manuel avant toute utilisation...

Страница 2: ...rials close to the unit while operating as it is fire hazard Use safety cable when fixes this unit Maximum ambient temperature is 40 C and don t operate it where the temperature is higher than this Th...

Страница 3: ...01 P 35 Press mode button until it shows S xx 01 99 FL Press up or down can adjust the build in programs speed Press the mode button show F xx 00 99 Press the button up or down to adjust the build in...

Страница 4: ...CH1 0 255 RED CH2 0 255 GREEN CH3 0 255 BLUE CH4 0 255 MASTER DIMMER 0 6 CH1 CH4 DIMMER juil 13 PR 01 14 20 PR 02 21 27 PR 03 28 34 PR 04 35 41 PR 05 42 48 PR 06 49 55 PR 07 56 62 PR 08 63 69 PR 09 70...

Страница 5: ...PR 32 231 237 PR 33 238 244 PR 34 CH5 245 255 PR 35 CH6 0 255 Adjust speed 0 15 NO FUNCTION CH7 16 255 Strobe R G B DIMMER PR XX DMX working mode 3 36c 36CH CHANNEL VALUE FUNCTION SECTION CH1 0 255 R...

Страница 6: ...0 255 BLUE CH28 0 255 RED 10 CH29 0 255 GREEN CH30 0 255 BLUE CH31 0 255 RED 11 CH32 0 255 GREEN CH33 0 255 BLUE CH34 0 255 RED 12 CH35 0 255 GREEN CH36 0 255 BLUE 3 4 M S mode Press the mode above 2...

Страница 7: ...es when it shows COL it is the static color mode Press the mode button when it shows 1 r or 2 rg or 3 g or 4 gb or 5 b or 6 rb or 7 FL or 8 0F Press the up or down to choose the single color Press the...

Отзывы: