Dear Customer

The Clifton Range® is part of Nickel-Electro Ltd a family firm based in Weston-Super-

Mare which was incorporated as a limited company in 1941 but its roots can be traced 

back to 1935 when the business first started. Now in its 3rd generation of family 

members, the company prides itself on being a strongly established, independant 

British manufacturer. 

Thank you for purchasing this piece of Clifton Range® temperature control equipment. 

To get the best performance from your equipment and for your own safety please read 

these instructions carefully before use. 

GENERAL NOTES

1.  Always follow good teaching and safety practice. CLEAPPS October 2005 report 

recommends a Risk Assessment is produced. 

2.  Spirometers should only be used under the direct supervision of a teacher who is 

experienced in their correct use. Teachers are reminded that they have  a special 

responsbility when pupils are used as the subject of experiments. Investigations 

involving unusual ventilation of the lungs can be dangerous to epileptics, 

ashmatics or children suffering from bronchial disorders. 

3.  When using spirometers for gas analysis be aware of the possible consequences 

of hyperventilation or of holding the breath. If the experiment requires a supply of 

oxygen it must be of medical quality. 

4.  In experiments where indication soda-lime is used to absorb the expired carbon 

dioxide, the spirometer float must be filled with medical grade oxygen.  Contact 

BOC Healthcare for further information.

5.  A kymograph or datalogger system is required to record results. We recommend a 

Logit from Griffen Education or a Data Harvester from Scientific and Chemical with 

neccessary motion sensor fitted to logger. 

Содержание Clifton Range SM-1

Страница 1: ...High quality products at affordable prices SPIROMETER SM 1...

Страница 2: ......

Страница 3: ...should only be used under the direct supervision of a teacher who is experienced in their correct use Teachers are reminded that they have a special responsbility when pupils are used as the subject o...

Страница 4: ...designed to offer minimum resistance to air flow This means greater comfort for the user and more realistic results The spirometer enables rate of breathing volumes of breaths and consumption of oxy...

Страница 5: ...anywhere in the system as oxygen can form explosive compounds with these materials 4 Immerse the mouth piece into sterilizing solution Spare mouth pieces are available from your distributor BX0612 Dis...

Страница 6: ...res turn off the supply set the valve to SPIROMETER and press down on the float This forces the oxygen out through the mouthpiece and flushes the air out of the system Do not allow oxygen to be discha...

Страница 7: ...by the amplitude of the trace 4 Respiratory rate the number of breathes per minute or more formally the number of movements indicative of inspiration and expiration is usually determined by counting...

Страница 8: ...new condition Descale by adding 1 litre of vinegar to water and leave for an hour Empty and brush the lime away Rinse thoroughly afterwards The stainless steel crevice free tank should provide years o...

Страница 9: ...y materials or workmanship in any goods manufactured supplied by Nickel Electro Ltd which under proper and normal conditions of use may develop within a period of one years from the date of delivery 3...

Страница 10: ...for specialist engineers currently in force 7 In the event of replacement with a new or reconditioned model the replacement unit will continue the warranty period of the original equipment 8 If any g...

Страница 11: ...rbalance weight is supplied Slide the weight onto the rod and tighten the thumb screw This is the counterweight assembly for the float 2 The large white moulding is the float assembly a metal frame is...

Страница 12: ...rew is fitted Each one locates into a dimple on the top rim of the tank The float assembly will see saw adjust the counter balance weight accordingly 5 In a polythene bag there are a number of loose p...

Страница 13: ...ic cap assembly by pushing it back into the top of the container Tighten the wing nut to seal the container 4 Connect the oxygen supply to the outlet fitted in the cap Assembling the Flexible Hoses to...

Страница 14: ...iece is a tight fit into the hose and this is as it should be Hold the hose and tilt the T piece back slightly Push 3 4 of the T piece inside the hose gently wiggle and rotate both parts to fully inse...

Страница 15: ...old together whilst breathing Option 2 BX0978 Disposable Breathing Filter fit the accessory adaptor MXM0894 into the T piece Push the disposable filter into the adaptor Fitting the Pen Arm for Recordi...

Страница 16: ...SPIROMETER SM 1 CLIFTON RANGE 1 YEAR WARRANTY...

Страница 17: ...SPIROMETER SM 1 CLIFTON RANGE 1 YEAR WARRANTY...

Страница 18: ...SPIROMETER SM 1 CLIFTON RANGE 1 YEAR WARRANTY...

Страница 19: ...SPIROMETER SM 1 CLIFTON RANGE 1 YEAR WARRANTY...

Страница 20: ...SPIROMETER SM 1 CLIFTON RANGE 1 YEAR WARRANTY...

Страница 21: ...BX0854 Issue 3 April 2020...

Отзывы: