Cleaning and Maintenance Instructions

Before cleaning the instrument, it needs to be disconnected from the electrical supply!

Cleaning the Exterior of the Instrument

1.  The housing of the instrument and control panel should be cleaned at least once a 

week (depending on working conditions) a small quantity of mild detergent applied 

using a soft cloth. 

2.  Electrical parts should not be in contact with water or detergent. 

Cleaning the Interior of the Instrument

1.  The heating chamber should be emptied of any sample before cleaning.

2.  Only water or water with mild detergent should be used, and should be applied with 

a soft cloth.

3.  Having fi nished cleaning, you should allow the instrument to fully dry and re-fi t all 

accessories which were removed prior to cleaning.

4.  During cleaning care should be taken not to damage the internal temperature sensor.

5.  The base of the drying chamber can become discoloured over time due to the 

heaters located under the metal base. This is completely normal and does not effect 

performance of the Drying Oven.

6.  Electrical parts should not be in contact with water or detergent. 

WARNING:

 

 

 

SCOURING PADS OR DE-SCALING AGENTS MUST NOT    

 

 

 

BE USED TO CLEAN THIS INSTRUMENT.

Taking Care of the Instrument When Not in Use:

1.  Remove all objects from the drying chamber.

2.  Disconnect the instrument from the main power supply.

3.  Clean and dry the heating chamber.

4.  Leave the door open to avoid nasty smells.

5.  Store in temperature between 0

o

C and 50

o

C and a maximum relative humidity of 

70%.

PAT Testing

 

 

 

Portable appliance testing should be carried out by a qualifi ed   

 

 

 

person.  This equipment should not be fl ash tested! 

!

!

CLIFTON RANGE DRYING OVEN NE9 SERIES

8

Содержание Clifton Range NE9-112S

Страница 1: ...NE9S SERIES Fan Circulation Drying Ovens NICKEL ELECTRO LIMITED Oldmixon Crescent Weston Super Mare North Somerset BS24 9BL United Kingdom Clifton Range...

Страница 2: ...perature Program Continued 13 Starting the Temperature Program 14 Immediately Starting Program Option 14 Delay Starting Program Option 14 Date Time Starting Program Option 15 Program Running Controls...

Страница 3: ...ltage to that specified on the rating label positioned on the rear of the unit 6 Ensure that the power supply has an earth ground terminal Amendments Issue 1 March 2013 Initial Issue Symbols This symb...

Страница 4: ...ronments 5 Store inflammable or volatile substances inside the instrument touch live parts of the instrument operate the instrument with damp hands place vessels containing fluids on the instrument cl...

Страница 5: ...ed on a hard surface in a dry airy place with low relative air humidity maximum 60 RH no condensation The ambient temperature should be 10 to 28 C 2 The instrument should not be placed in direct sunli...

Страница 6: ...e top of the rear of the instrument these are indicated below Exhaust flap Mains power lead Fuse socket Controls cooling fan USB connection RS232 connection Mains power switch on far side Fan for Dryi...

Страница 7: ...Range Ambient to 250 C 0 4 C at 105 C Heater Power 1100 Watts NE9 56S Dimensions External 590w x 560d x 690h mm Internal 395w x 360d x 395h mm Capacity 56L Weight 61Kgs 135lbs Temperature Range Ambie...

Страница 8: ...emperature sensor 5 The base of the drying chamber can become discoloured over time due to the heaters located under the metal base This is completely normal and does not effect performance of the Dry...

Страница 9: ...e Drying Oven on using the mains switch located top right hand side controls the instrument will enter an auto diagnostics routine if an error is found the instrument stops or an appropriate screen is...

Страница 10: ...re display off keypads illuminated Resume from standby touch the ON OFF key and following the screen instruction If the unit is left unattended and not used a clock face will appear in the display Sho...

Страница 11: ...rent temperature in the chamber Status information heating and fan indicators Turn OFF ON standby keypad Program and set temperature status Date and Time CANCEL EXIT keypad ACCEPT ENTER keypad SCROLL...

Страница 12: ...PROGRAMS confirm selection with enter key Touch to highlight list then Program1 then edit Editing and Setting the Temperature Program The following instructions are for editing and setting the tempera...

Страница 13: ...adjust the value up or down using the arrow keys Touch to enter and save the value Touch to exit Program1 touch to confirm and save changes A protection screen appears should you need to set an alarm...

Страница 14: ...uch or to select the option and then enter Immediately starting program option Program1 status screen indicating set temperature heating fan speed and actual chamber temperature Delay starting program...

Страница 15: ...uch to enter settings a border appears around time value hh mm touch to highlight the hour value hh then touch either or to adjust and then to acknowledge new hour value Now mm is highlighted touch or...

Страница 16: ...creen advice touch and hold until cleared Stopping the program 1 Touch twice and stop appears in menu touch to confirm ALARM If an alarm has been triggered a warning triangle appears in top left hand...

Страница 17: ...ctory pre set 0 closed The following instructions are for editing and setting the exhaust which allows air from the chamber to escape settings 0 closed to 100 open Recommend left closed at 0 c losed F...

Страница 18: ...Program screen appears touch underneath S1 FLA then set Touch under to increase or to decrease then set to exit to save changes acknowledge yes or no CLIFTON RANGE DRYING OVEN NE9 SERIES 18...

Страница 19: ...g and setting date and time Touch and repeat then touch or to highlight SETUP confirm selection with enter key Touch to highlight Clock then to enter clock settings A border appears around time value...

Страница 20: ...en touch either or to adjust and then to acknowledge new hour value and continue with mm month and dd day values When changes have been completed touch and to exit Door Open CLIFTON RANGE DRYING OVEN...

Страница 21: ...give the serial number and description of the goods order number and date of delivery and will not apply where any names or serial numbers or other information which may be attached to or inscribed u...

Страница 22: ...to ensure that the loan equipment is returned in the same condition as it was received and if required decontaminated with a signed decontamination sheet enclosed with the instrument It is the custom...

Страница 23: ...confirm the declaration Nickel Electro Limited Oldmixon Crescent Weston Super Mare North Somerset BS24 9BL United Kingdom Conforms with the requirements of the following standards BS EN 61010 1 BS EN...

Отзывы: