EN
English –
5
mensions A and B.
Note
– The rear bracket provided with the gearmotor has a length of 150
mm; in the case of special applications or an outward opening gate (
fig. 6
)
the bracket model PLA6 (optional accessory) may be used.
CAUTION!
– Before securing the rear bracket, check the fixing zone of
the front bracket is in a solid part of the leaf, as this bracket must be
fixed at a different height of the rear bracket (fig. 8).
04.
At this point, fix the bracket using dowels, screws and washers required
(not supplied).
3.5.2 – Installation of front fixing bracket
The front bracket provided with the gearmotor must be welded directly onto the
gate leaf. If this is not possible, use the bracket model PLA8 (optional accessory).
01.
With reference to value A as obtained from procedure 3.5.1, identify the same
value in the first column on table 1; thus, read the corresponding value E.
02.
On the leaf report the E and temporarily position the bracket in correspon-
dence to this value;
IMPORTANT
– ensure that the distance between the
two rotation pins (i.e. the D shown in fig. 4 / 6) is 700 mm. If necessary cor-
rect the E by moving the bracket on the leaf until the length of 700 mm for
the D is obtained.
03.
Establish the height in which to position the front bracket, referring to
fig. 8
;
04.
Fix the bracket to the solid part of the gate leaf.
3.5.3 – Installation of the gear motor on the fixing brackets
•
Installing the gear motor on
the rear bracket
:
01.
Fix the gear motor to the bracket as shown in
fig. 9
using the screw, washer
and nut supplied;
02.
Tighten the nut to the end and then loosen by 1/10 of a turn to allow mini-
30 mm
8
7
mum clearance between the parts.
•
Installing the gear motor
on the front bracket
:
01.
Fix the gear motor to the bracket as shown in
fig. 10
using the screw,
washer and nut supplied;
02.
Tighten the screw to the end.
03.
Fix the label provided in the package, dealing with the unblocking and block-
ing operations of the gear motor, permanently close to the gear motor.
3.6 - Setting the mechanical limit switch
The mechanical limit switch allows to set the stop position of the gate leaf, in this
way, it is not necessary to use the stop blocks and the leaf does not hit against
these at the end of the manoeuvre.
WARNING
– In the event of applications with a gate equipped with open-
ing towards the outside (fig. 6) it is necessary to invert the power supply
wires.
Set the
limit switch in Opening
of the gear motor as follows:
01.
Unblock the gear motor as shown
in fig. 14
;
02.
Loosen the mechanical stop screw;
03.
Bring the gate leaf manually to the
Open
position required;
04.
Then, bring the mechanical stop to the end of the pin and block the screw
(
fig. 11
).
05.
Bring the leaf manually to the
Close
position and block the gear motor.
www.metalines.com