background image

EN

English – 

5

mensions A and B.

Note

– The rear bracket provided with the gearmotor has a length of 150

mm; in the case of special applications or an outward opening gate (

fig. 6

)

the bracket model PLA6 (optional accessory) may be used.

CAUTION!

– Before securing the rear bracket, check the fixing zone of

the front bracket is in a solid part of the leaf, as this bracket must be
fixed at a different height of the rear bracket (fig. 8).

04.

At this point, fix the bracket using dowels, screws and washers required
(not supplied).

3.5.2 – Installation of front fixing bracket

The front bracket provided with the gearmotor must be welded directly onto the
gate leaf. If this is not possible, use the bracket model PLA8 (optional accessory).

01.

With reference to value A as obtained from procedure 3.5.1, identify the same
value in the first column on table 1; thus, read the corresponding value E.

02.

On the leaf report the E and temporarily position the bracket in correspon-
dence to this value; 

IMPORTANT

– ensure that the distance between the

two rotation pins (i.e. the D shown in fig. 4 / 6) is 700 mm. If necessary cor-
rect the E by moving the bracket on the leaf until the length of 700 mm for
the D is obtained.

03.

Establish the height in which to position the front bracket, referring to 

fig. 8

;

04.

Fix the bracket to the solid part of the gate leaf.

3.5.3 – Installation of the gear motor on the fixing brackets

Installing the gear motor on 

the rear bracket

:

01.

Fix the gear motor to the bracket as shown in 

fig. 9

using the screw, washer

and nut supplied;

02.

Tighten the nut to the end and then loosen by 1/10 of a turn to allow mini-

30 mm

8

7

mum clearance between the parts.

Installing the gear motor 

on the front bracket

:

01.

Fix the gear motor to the bracket as shown in 

fig. 10

using the screw,

washer and nut supplied;

02.

Tighten the screw to the end.

03.

Fix the label provided in the package, dealing with the unblocking and block-
ing operations of the gear motor, permanently close to the gear motor.

3.6 - Setting the mechanical limit switch

The mechanical limit switch allows to set the stop position of the gate leaf, in this
way, it is not necessary to use the stop blocks and the leaf does not hit against
these at the end of the manoeuvre.

WARNING 

– In the event of applications with a gate equipped with open-

ing towards the outside (fig. 6) it is necessary to invert the power supply
wires. 

Set the

limit switch in Opening 

of the gear motor as follows:

01.

Unblock the gear motor as shown 

in fig. 14

;

02.

Loosen the mechanical stop screw;

03.

Bring the gate leaf manually to the 

Open

position required;

04.

Then, bring the mechanical stop to the end of the pin and block the screw
(

fig. 11

).

05.

Bring the leaf manually to the 

Close

position and block the gear motor.

www.metalines.com

[email protected]

Содержание WG4024

Страница 1: ...Wingo4024 EN Instructions and warnings for installation and use Swing gate opener www metalines com sales metalines com ...

Страница 2: ... be disposed of respecting the local regulations in force GENERAL SAFETY WARNINGS AND PRECAUTIONS 1 This product is intended to be used for automating swing gates or doors in an exclusively residential context CAUTION Any other use different to that described and in ambient conditions different to those set out in this man ual is to be considered improper and forbidden The product is an electromec...

Страница 3: ... fig 4 6 on the fixing side 02 On graph 2 identify dimension C found and trace a horizontal line that de termines the value of dimension B as shown in the example of fig 5 the meeting point with line r i l installation line recommended determines the value of the angle of maximum opening From this point trace a vertical line as shown in the example of fig 5 to determine the value of dimension A If...

Страница 4: ...30 mm mm 90 100 100 110 110 120 120 130 mm mm mm C B 110 120 130 130 B C A E A mm E mm 100 600 110 590 120 580 130 570 140 560 150 550 160 540 170 530 180 520 190 510 200 500 210 490 220 480 230 470 TABLE 1 4 5 D 7 0 0 m m 6 www metalines com sales metalines com ...

Страница 5: ...cket to the solid part of the gate leaf 3 5 3 Installation of the gear motor on the fixing brackets Installing the gear motor on the rear bracket 01 Fix the gear motor to the bracket as shown in fig 9 using the screw washer and nut supplied 02 Tighten the nut to the end and then loosen by 1 10 of a turn to allow mini 30 mm 8 7 mum clearance between the parts Installing the gear motor on the front ...

Страница 6: ...eck the devices which make up the automatism The inspection of the entire system must be performed by expert and qual ified staff who must take responsibility of the tests requested depending on the risk involved and to check compliance of what is set out by laws rules and regulations and in particular all the requirements of regulation EN 12445 which establishes the testing methods to verify gate...

Страница 7: ...ical power and perform all the tests and checks envisaged in chapter 5 For the other devices present in the system refer to the individual instruction manuals PRODUCT MAINTENANCE 6 05 Using the control or shutdown devices envisaged key selector switch con trol buttons or radio transmitters perform a number of opening closing and stopping tests of the gate and check it behaves as it should 06 Check...

Страница 8: ...e of manufacturer NICE S p A Address Via Pezza Alta N 13 31046 Rustignè di Oderzo TV Italy Person authorized to provide technical documentation Mr Oscar Marchetto Address Via Pezza Alta N 13 31046 Rustignè di Oderzo TV Italy Product type 24 V D C electromechanical gearmotor for swing gate Model Type Wingo4024 Accessories none The undersigned Luigi Paro as Managing Director hereby declares under hi...

Страница 9: ... nance every 6 months for normal domestic use but this period may vary depending on the intensity of use Any control maintenance or repair work must be performed by qualified personnel Even if you consider yourself able to perform the work do not modify the sys tem and the programming parameters or adjust the automation it is the responsibility of the fitter The inspection periodic maintenance wor...