Contents

GENERAL SAFETY WARNINGS AND PRECAUTIONS

STEP 1

Working in safety!  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Installation warnings  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

KNOWLEDGE OF THE PRODUCT AND PREPARATION FOR
INSTALLATION

STEP 2

2.1

- Product description and intended use  . . . . . . . . . . . . . . . . . . . . . . . . . 2

2.2

- Components used to set up a complete system  . . . . . . . . . . . . . . . . .2

STEP 3

Preliminary checks for installation

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

3.1

- Checking suitability of the environment and door to be automated  . . . 3

3.2

- Checking product application limits  . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

STEP 4

4.1

- Preliminary set-up work  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

- 4.1.

1 - Typical reference system

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

- 4.1.

2 - Establishing positions of components

 . . . . . . . . . . . . . . . . . . . . . . 3

- 4.1.

3 - Establishing the device connection layout

 . . . . . . . . . . . . . . . . . . . 3

- 4.1.

4 - Checking the tools required for the work

 . . . . . . . . . . . . . . . . . . . . 3

- 4.1.

5 - Completing the set-up work

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

4.2

- Laying the electric cables  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

INSTALLATION: COMPONENT ASSEMBLY AND CONNECTION

STEP 5

5.1

- Installing the automation components  . . . . . . . . . . . . . . . . . . . . . . . . . 4

5.2

- Fixing the automation to the wall, ceiling, and door  . . . . . . . . . . . . . . . 4

STEP 6

System device installation and connection  . . . . . . . . . . . . . . . . . . . . . . . . 5

POWER SUPPLY CONNECTION

STEP 7

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

INITIAL START-UP AND ELECTRICAL CONNECTIONS CHECK

STEP 8

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

PROGRAMMING THE AUTOMATION

STEP 9

9.1

- Memorisation of transmitter mod. FLO4R-S  . . . . . . . . . . . . . . . . . . . . 6

9.2

- Memorising the door 

“Opening”

and 

“Closing”

travel limit positions  . . .6

DJUSTMENTS AND OTHER OPTIONAL FUNCTIONS

10

- Automation operation adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

11

- Memorisation of a new transmitter with control unit “in the vicinity” . . . . 7

12

- Deleting data from the Control unit memory  . . . . . . . . . . . . . . . . . . . . . 7

WHAT TO DO IF...

(troubleshooting guide)

 . . . . . . . . . . . . . . . . . . . . . . . 8

TASKS RESERVED FOR QUALIFIED TECHNICIANS

Connecting the automation to the electrical mains  . . . . . . . . . . . . . . . . . . 8

Automation testing and commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Product disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

CE declaration of conformity  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

TECHNICAL SPECIFICATIONS OF COMPONENTS

 . . . . . . . . . . . . . 10

OPERATION MANUAL AND IMAGES

 . . . . . . . . . . . . . . . . . . . . . . . I - XVI

ENGLISH

E

N

Содержание Shel50Kit

Страница 1: ...so FR Instructions et avertissements pour l installation et l utilisation ES Instrucciones y advertencias para la instalaci n y el uso DE Installierungs und Gebrauchsanleitungen und Hinweise PL Instru...

Страница 2: ......

Страница 3: ...EMBLY AND CONNECTION STEP 5 5 1 Installing the automation components 4 5 2 Fixing the automation to the wall ceiling and door 4 STEP 6 System device installation and connection 5 POWER SUPPLY CONNECTI...

Страница 4: ...this occur disconnect the power supply immediately and contact a Nice service centre Use of the automation in these conditions constitutes a hazard never place automation components near to sources o...

Страница 5: ...th the technical specifications of the gearmotor Ensure that the area for mounting the gearmotor and guide is compatible with the overall dimensions of the automation to be installed Then ensure that...

Страница 6: ...the length of distance B consider ing the constraints of values A and E fig 3 If the door is UP AND OVER establish the length of distance B con sidering the constraints of value F fig 4 Note If values...

Страница 7: ...se a connection layout in series as shown in the example in fig 41 C to connect a series of devices with constant resistance 8 2 K use a parallel connection layout positioning the resistance 8 2K on t...

Страница 8: ...itter the keys must be memorised in the control unit memory Memorisation enables the association of each key with the required command selecting from the following 1 Step Step Corresponds to the seque...

Страница 9: ...ng key P1 press the transmitter key to be deleted if the control unit recognises this operation the green led emits a short flash after which the P1 key and transmitter key can be released TABLE 4 AUT...

Страница 10: ...utoma tion and not visible from the latter it must be fitted with a lockout facility to pre vent inadvertent or unauthorised connection Note The disconnect devices are not supplied with the product AU...

Страница 11: ...claration correspond to those of the last revision available of the official document deposited at the registered offices of Nice S p a before printing of this manual The text herein has been re edite...

Страница 12: ...ode Self learning of door opening and closing positions and calculation of deceleration and partial open points Use in particularly acid or saline No potentially explosive atmospheres Protection class...

Страница 13: ...legislation locally in force In the event of malfunctions or power failures While you are waiting for the technician to come or for the power to be restored if your system is not equipped with buffer...

Страница 14: ...IONAAL PROJECTING DEBORDANTE D BORDANTE DESBORDANTE AUSFAHREND WYSTAJ CA BUITEN DE GEVEL DRAAIEND NON PROJECTING NON DE BORDANTE NON D BORDANTE NO DESBORDANTE NICHT AU SFAHREND NIEWYSTAJ CA BINNEN DE...

Страница 15: ...9 6 7 8 a b c d l e f h m g g...

Страница 16: ...V3 5 x 15 10 A A A B A C 11 13 14 15 16 12 V6 x 30 R06 open aperta ouverte abierta ge ffnet otwarta open b a V8 x 45...

Страница 17: ...19 17 a 17 b 20 22 18 M8 R8 x 24 V8 x 45 21 23 M6 V6 x 18...

Страница 18: ...24 V6 x 14 M6 B 4 400 mm 25 90 25 a 26 29 30 28...

Страница 19: ...31 32 33 34 35 1 2 1 2 3 4 TX RX 1 2 3 4 5 36 Input STOP 0 VOLT LINE 24 Vcc Input STEP BY STEP Input PHOTO 1 2 3 4 5 1 1 2 1 2 3 4 2 3 4 5 TX RX 1 2 1 2 3 4 TX RX 37 1 2 3 4 5 38...

Страница 20: ...1 2 3 4 5 40 1 2 3 4 5 41 1 2 3 4 5 42 1 2 3 4 5 NA NC 43 44 45 P1 Green Led Led verde Led verte Led verde gr ne Led Zielona dioda Groene led Red Led Led rosso Led rouge Led rojo rote Led Czerwona di...

Отзывы: