The device provides the association of 10 groups:

1st association group – “Lifeline” reports the device status and allows for assigning single device only (main controller by default).
2nd association group –  “RGBW Sync” allows to synchronize state of other RGBW-Control devices.

3rd association group –  “On/Off (IN1)” is used to turn the associated devices on/off reflecting IN1 operation.
4th association group – “Dimmer (IN1)” is used to change level of associated devices reflecting IN1 operation.
5th association group –  “On/Off (IN2)” is used to turn the associated devices on/off reflecting IN2 operation.
6th association group – “Dimmer (IN2)” is used to change level of associated devices reflecting IN2 operation.
7th association group –  “On/Off (IN3)” is used to turn the associated devices on/off reflecting IN3 operation.
8th association group – “Dimmer (IN3)” is used to change level of associated devices reflecting IN3 operation.
9th association group –  “On/Off (IN4)” is used to turn the associated devices on/off reflecting IN4 operation.
10th association group – “Dimmer (IN4)” is used to change level of associated devices reflecting IN4 operation.

Note. 

Association groups 2-10 can be triggered only from buttons connected to IN1-IN4 and will not work for 0-10V sensors.

The device allows to control 5 regular or multichannel devices per an association group, with the exception of “Lifeline” that is reserved solely 

for the controller and hence only 1 node can be assigned.

Table A3 - Assocation groups mapping

Root

Endpoint

Association group in endpoint

Association Group 1

Endpoint 1-9*

Association Group 1

Association Group 2

Endpoint 1

Association Group 2

Association Group 3

Endpoint 2

Association Group 2

Association Group 4

Endpoint 2

Association Group 3

Association Group 5

Endpoint 3

Association Group 2

Association Group 6

Endpoint 3

Association Group 3

Association Group 7

Endpoint 4

Association Group 2

Association Group 8

Endpoint 4

Association Group 3

Association Group 9

Endpoint 5

Association Group 2

Association Group 10

Endpoint 5

Association Group 3

* max nodes supported: 0

Table A4 - Basic commands mapping

Command

Root

Endpoints

1-5

6-9

Basic Set

= EP1

Switch 

Multilevel Set

Basic Get

= EP1

Switch 

Multilevel Get

Sensor 

Multilevel Get

Basic Report

= EP1

Switch 

Multilevel Report

Sensor 

Multilevel Report

Table A5 - RGBW mode: commands sent to association groups for parameter 150 set to 0

Input

1 and 2 click

Hold

Release

Input 1

Basic Set: 3rd, Multilevel Set: 4th, 

Switch Color Set: 2nd

Multilevel Start Level Change: 4th

Multilevel Stop Level Change: 

4th, Switch Color Set: 2nd

Input 2

Basic Set: 5th, Multilevel Set: 6th, 

Switch Color Set: 2nd

Multilevel Start Level Change: 6th

Multilevel Stop Level Change: 

6th, Switch Color Set: 2nd

Input 3

Basic Set: 7th, Multilevel Set: 8th, 

Switch Color Set: 2nd

Multilevel Start Level Change: 8th

Multilevel Stop Level Change: 

8th, Switch Color Set: 2nd

Input 4

Basic Set: 9th, Multilevel Set: 10th, 

Switch Color Set: 2nd

Multilevel Start Level Change: 10th

Multilevel Stop Level Change: 

10th, Switch Color Set: 2nd

Содержание RGBW-Control

Страница 1: ...EN Instructions and warnings for installation and use Universal remote control for RGB RGBW and other LEDs RGBW Control Nice...

Страница 2: ...few shorter strips in parallel connection instead of one long strip connected serially The device is designed for installation in a wall switch box of depth not less than 60mm The switch box and elec...

Страница 3: ...nput red LED color recommended OUT2 output connector controlled by IN2 input green LED color recommended OUT3 output connector controlled by IN3 input blue LED color recommended OUT4 output connector...

Страница 4: ...manual 3 Quickly three times click the service button 4 If you are adding in Security S2 Authenticated input the underlined part of the DSK label on the box 5 LED will start blinking yellow wait for...

Страница 5: ...ds in HSB mode HSB mode is enabled by setting parameter 150 to 1 Inputs correspond to different components in HSB colour space IN1 Hue IN2 Satu ration IN3 Brightness and IN4 input controls OUT4 output...

Страница 6: ...is missing or inoperable Certain device removal can be achieved by the procedure of removing described 7 ACTIVATING SCENES The device can activate scenes in the Z Wave controller by sending scene ID...

Страница 7: ...ence only 1 node can be assigned Table A3 Assocation groups mapping Root Endpoint Association group in endpoint Association Group 1 Endpoint 1 9 Association Group 1 Association Group 2 Endpoint 1 Asso...

Страница 8: ...el 2 Momentary switch Central Scene 3 Toggle switch switch state on every input change Central Scene 4 Toggle switch contact closed ON contact opened OFF Central Scene Default setting 2 momentary swit...

Страница 9: ...ting 0x05 0xFF 0x00 0x00 Water Alarm any notification no action Parameter size 4 bytes Parameter 32 Alarm configuration 3rd slot Description This parameter determines to which alarm frames and how the...

Страница 10: ...ings 1 Key pressed 1 time 2 Key pressed 2 times 4 Key pressed 3 times 8 Key hold down and key released Default setting 15 Parameter size 1 byte Parameter 41 Input 2 sent scenes Description This parame...

Страница 11: ...o the main controller Energy reports are sent no often than every 30 seconds Available settings 0 reports are disabled 1 500 0 01 5 kWh change in energy Default setting 10 0 1 kWh Parameter size 2 byt...

Страница 12: ...eserved for separate channel from least significant IN1 to most significant IN4 Applicable for Basic Set and Switch Multilevel Set commands Available settings For every byte 0 99 255 Default setting 0...

Страница 13: ...ASIC 0x20 V1 YES Multichannel Command Class MULTICHANNEL CC ROOT Endpoint 1 Generic Device Class GENERIC_TYPE_SWITCH_MULTILEVEL Specific Device Class SPECIFIC_TYPE_COLOR_TUNABLE_MULTILEVEL Command Cla...

Страница 14: ...S_SECURITY_2 0x9F COMMAND_CLASS_SENSOR_MULTILEVEL 0x31 COMMAND_CLASS_APPLICATION_STATUS 0x22 Description EP6 reports the Voltage measured on Input 1 EP7 reports the Voltage measured on Input 2 EP8 rep...

Страница 15: ...CC Endpoint 6 7 8 and 9 Sensor Type Scale Precision Size Description VOLTAGE V 1 2B Analog input 1 4 Lifeline reports ROOT COMMAND_CLASS_DEVICE_RESET_LOCALLY 0x5A DEVICE_RESET_LOCALLY_NOTIFICATION 0x0...

Страница 16: ...ution degree 2 Software class Class A Maximum phase to ground voltage of the supply source Supplied by external SELV source up to 24V DC Protection against electric shock class Class III control Class...

Страница 17: ...ances which if disposed of into the environment may cause serious damage to the environment or physical health As indicated by the symbol alongside disposal of this product in domestic waste is strict...

Страница 18: ...www niceforyou com Nice SpA Oderzo TV Italia info niceforyou com IS0845A00EN_17 03 2022...

Отзывы: