The device provides the association of 10 groups:
1st association group – “Lifeline” reports the device status and allows for assigning single device only (main controller by default).
2nd association group – “RGBW Sync” allows to synchronize state of other RGBW-Control devices.
3rd association group – “On/Off (IN1)” is used to turn the associated devices on/off reflecting IN1 operation.
4th association group – “Dimmer (IN1)” is used to change level of associated devices reflecting IN1 operation.
5th association group – “On/Off (IN2)” is used to turn the associated devices on/off reflecting IN2 operation.
6th association group – “Dimmer (IN2)” is used to change level of associated devices reflecting IN2 operation.
7th association group – “On/Off (IN3)” is used to turn the associated devices on/off reflecting IN3 operation.
8th association group – “Dimmer (IN3)” is used to change level of associated devices reflecting IN3 operation.
9th association group – “On/Off (IN4)” is used to turn the associated devices on/off reflecting IN4 operation.
10th association group – “Dimmer (IN4)” is used to change level of associated devices reflecting IN4 operation.
Note.
Association groups 2-10 can be triggered only from buttons connected to IN1-IN4 and will not work for 0-10V sensors.
The device allows to control 5 regular or multichannel devices per an association group, with the exception of “Lifeline” that is reserved solely
for the controller and hence only 1 node can be assigned.
Table A3 - Assocation groups mapping
Root
Endpoint
Association group in endpoint
Association Group 1
Endpoint 1-9*
Association Group 1
Association Group 2
Endpoint 1
Association Group 2
Association Group 3
Endpoint 2
Association Group 2
Association Group 4
Endpoint 2
Association Group 3
Association Group 5
Endpoint 3
Association Group 2
Association Group 6
Endpoint 3
Association Group 3
Association Group 7
Endpoint 4
Association Group 2
Association Group 8
Endpoint 4
Association Group 3
Association Group 9
Endpoint 5
Association Group 2
Association Group 10
Endpoint 5
Association Group 3
* max nodes supported: 0
Table A4 - Basic commands mapping
Command
Root
Endpoints
1-5
6-9
Basic Set
= EP1
Switch
Multilevel Set
–
Basic Get
= EP1
Switch
Multilevel Get
Sensor
Multilevel Get
Basic Report
= EP1
Switch
Multilevel Report
Sensor
Multilevel Report
Table A5 - RGBW mode: commands sent to association groups for parameter 150 set to 0
Input
1 and 2 click
Hold
Release
Input 1
Basic Set: 3rd, Multilevel Set: 4th,
Switch Color Set: 2nd
Multilevel Start Level Change: 4th
Multilevel Stop Level Change:
4th, Switch Color Set: 2nd
Input 2
Basic Set: 5th, Multilevel Set: 6th,
Switch Color Set: 2nd
Multilevel Start Level Change: 6th
Multilevel Stop Level Change:
6th, Switch Color Set: 2nd
Input 3
Basic Set: 7th, Multilevel Set: 8th,
Switch Color Set: 2nd
Multilevel Start Level Change: 8th
Multilevel Stop Level Change:
8th, Switch Color Set: 2nd
Input 4
Basic Set: 9th, Multilevel Set: 10th,
Switch Color Set: 2nd
Multilevel Start Level Change: 10th
Multilevel Stop Level Change:
10th, Switch Color Set: 2nd