Nice Pro-LT Скачать руководство пользователя страница 3

TABLE OF CONTENTS 

WARRANTY __________________________________________________________________

VERIFICATION OF  OPERATOR  AND  HARDWARE

.

 ________________________________ 

SPECIFICATIONS  _____________________________________________________________ 

SAFETY  INSTRUCTIONS  ______________________________________________________ 

INSTALLATION   _______________________________________________________________ 

LIMIT  SWITCH  ADJUSTMENT __________________________________________________ 

CONNECTION OF  POWER SUPPLY AND CONTROL STATION ______________________

 

CONNECTION OF REVERSING EDGE DEVICE AND CONTROL ACCESSORIES _______ 

CLUTCH  ADJUSTMENT  _______________________________________________________ 

BRAKE  ADJUSTMENT  ________________________________________________________ 

EMERGENCY  MANUAL  OPERATION  ____________________________________________ 

OPERATOR  MAINTENANCE  ___________________________________________________ 

MECHANlCAL ORA WINGS AND PARTS LISTS ___________________________________ 

ELECTRICAL DIAGRAMS _____________________________________________________

_

PAGE: 

10 

11 

12 

DO NOT CONNECT TO ELECTRICAL 

POWER DURING INSTALLATION OR 

SERVICING OF OPERATOR 

13 

13 

14 

16 

18 

1

5

 

Содержание Pro-LT

Страница 1: ...EN Instructions and warnings for installation and use Automation for sectional overhead doors Pro LT...

Страница 2: ...ed at the option of Nice with repaired new or re manufactured parts NICE CANADA will not be responsible for any extra charges incurred in the process of returning defective material All returned mater...

Страница 3: ...OWER SUPPLY AND CONTROL STATION ______________________ CONNECTION OF REVERSING EDGE DEVICE AND CONTROL ACCESSORIES _______ CLUTCH ADJUSTMENT _______________________________________________________ BRA...

Страница 4: ...voltage phase and amperage correspond to available power supply and door application Check that along with your operator you have received the following standard hardware 1 x OPEN CLOSE STOP 3 button...

Страница 5: ...ble for model PRO LTB WIRING TYPE STANDARD C 2 Wiring constant pressure on close momentary contact on open and stop Wired to accept reversing edge radio control photocells loops and OPEN CLOSE devices...

Страница 6: ...ing Outdoor external devices should have security features to prevent unauthorized operation ofthe door Never cross under a moving door Press the OPEN device or activate quick release disconnect devic...

Страница 7: ...t be properly installed and working smoothly Remove all door locks prior to installation I Install control station away from all moving door parts within sight ofthe door and a minimum of 5 ft 1 5 m f...

Страница 8: ...to operator frame using four 3 8 x bolts and 3 8 serrated hex nuts provided TRACKSPACER CARRIAGEASSEMBLY TOWARDS OOOR HEX NUT 3 8 16UNC LOCK WASHER 3 8 TOWARDS OPERATOR TAKE UP BOLT 3 8 16UNC HEX NUT...

Страница 9: ...ine drawn earlier CARPENTER S LEVEL WALl 3 Mount a wood block or angle iron to the wall above the door opening as shown below The wall mounting bracket has 3 holes for anchoring to wood block or angle...

Страница 10: ...carriage spring pin by pulling on rope When installed the open side of notch should face the door 2 Using 3 8 bolts and nuts provided align the mounting holes of straight arm and curved arm so that pi...

Страница 11: ...LLY DISCONNECTED To adjust door travel 1 Open cycle Depress cam plate and spin Open limit cam away from Open limit switch to increase door travel or spin Open limit cam towards the Open limit switch t...

Страница 12: ...INSIDE CONTROL BOX POWER WlRING Use 1 1 8 2 85 cm diameter holes for all power wiring Connect single phase power supply to terminals L line and N neutral on three pole power terminal strip 0 1 PHASE...

Страница 13: ...External interlock tenninals 0 3 RADIII Dfl1III 1tif 4 Single button open close device Wire to terminals 7 and 8 on control terminal strip 5 Wire to terminals 3 and 6 on control Loop detectors photoce...

Страница 14: ...is de energized Wben solenoid is energized brake shoes should release from drum with sufficient clearance to avoid contact between shoes and drum To adjust brake tension tighten to increase or loosen...

Страница 15: ...ISK OF INJURY OR DEA TH DO NOT ATTEMPT TO USE EMERGENCY DISCONNECT I SYSTEM WHILE OPERATOR IS RUNNNG TO AVOID BEING STRUCK BY DOOR ARM DO NOT STAND DIRECTLY UNDER THE RELEASE ARM WHEN PULLING THE RELE...

Страница 16: ...hes if necessary 3 Verify and adjust clutch and brake Do not lubricate 4 Lubricate chains bearings and limit shaft 5 Verify that motor and operator runs smoothly and quietly Verify that carriage runs...

Страница 17: ...08 c s I D J DATE I APPROVED I DRAIJN BY UNLESS THER IISE SPECIFIED DIMENSI NS ARE IN INCHES TOLERANCES XX 01 ANGLES 30 REVISION A TITLE LIMITED DUTY OPERATOR PRO LT LTB WEIGHT lb I SIZE B I PAGE 1 1...

Страница 18: ...D HEX NUT 3 32UNF tl R irfRaNAf 37 PncH oRtrrE c rvl oFFsErLINK I coNN L NK EYWAY r 4 SO x 1 1 4 LG aFfuFN 3r16 x1 tc LoNG L MfiEDDUTYFRAMESUPPoRTI BR4q EII4 J H oirFD SELF RouNohicWAstsER HEAD scRFWr...

Страница 19: ...CLOSE THE DOOR PHASE PRo LT GJ l 2HP 110 MSLT GJ WW REV F I DATE 29 01 07 TECH HELP LINE CANADA H877l 888 1116 ll ll 1 888 816 8584 IF MOMENTARY OPERATION ON CLOSE 92 WIRING IS DESIRED THEN RE INSTAL...

Страница 20: ...C Canada H9P 2T5 Tel 514 822 1116 Toll Free 877 888 1116 CHICAGO 721 W Racquet Club Dr Addison IL USA 60101 Tel 630 501 1909 Toll Free 844 542 9025 ATLANTA 2885 N Berkeley Lake Rd Suite 7 Duluth GA US...

Отзывы: