12
1.Reversing Edge device
(must be no
rm
ally open contact):
Note:
If the door is controlled by any device or wired in such a manner that the door is
not
controlled by constant pressure on close then an appropriate reversing edge must be installed.
2.
Remove jumper between terminals 1 and 2 and wire interlock between these two
External interlock:
tenninals.
0
3.
RADIII (Dfl1III..
1tif�
4.
Single button open/close device: Wire to t
ermin
als 7 and 8 on control terminal strip.
5.
Wire to terminals 3 and 6 on control
Loop detectors, photocells and other reversing devices:
terminal strip.
6. 24 Volt power: Wire to terminals 1 and 9 on control terminal strip
CONTROL TERMINAL STRIP
®
®
®
®
® ®
® ® ®
�
2
3
4
5
6
7
8
�
®
®
®
®
®
® ®
Radio control receiver: Wire standard radio receiver to separate radio strip on side of control box or to
terminals 7, 8 and 9 on control terminal strip inside control box.