Nice Pro-LT Скачать руководство пользователя страница 12

11 

CTION OF POWER SUPPLY AND CONTROL STA 'fION

>'.

:

', . 

• 

.

• 

,{try�. 

.

WARNING 

COMPARE AVAILABLE POWER SUPPLY VOLTAGE TO OPERATOR NAMEPLATE PRIOR 

TO ELECTRICAL CONNECTION. FAILURE TO CONNECT APPROPRIATE POWER SUPPLY 

VOLTAGE MAY CAUSE SERIOUS DAMAGE TO OPERATOR. 

Refer to electrical diagrams inside control box cover or at the end of this manual prior to 

connection of power supply or control station. 

WARNING 

TO REDUCE THE RISK OF INTTJRY OR DEATH: 

ALL ELECTRJCAL CONNECTIONS SHOULD BE MADE BY A QUALIFIED SERVICE PERSON 

DO NOT ATTEMPT TO MAKE ELECTRICAL CONNECTIONS TO OPERATOR UNLESS 

POWER SUPPLY HAS BEEN DISCONNECTED AT FUSE BOX 

OPERA TOR MUST BE CONNECTED IN ACCORDANCE TO LOCAL ELECTRICAL CODES 

AND GROUNDED TO GREEN GROUND LUG LOCATED INSIDE CONTROL BOX 

POWER WlRING: Use 1-1/8" (2.85 cm) diameter holes for all power wiring. 

Connect single phase power supply to terminals L (line) and N (neutral) on three-

pole power terminal strip. 

1-PHASE 

3  BUTTON  CONTROL  STATION 

CONTROL WIRING: Use 7/8" (2.22 cm) diameter holes for all control 

wiring. Note: Do not run control wires and power wires in same conduit. 

-Install control station within clear sight of door but away from all moving parts of door or hardware.

Install Entrapment warning sign next to control station. Connect 3-butTon (open/close/stop)

push button station to tcnninals 2, 3, 4 and 5. Refer to electrical diagram for connection of two

3-button stations.

NOTE: After electrical connections are made, manually move door to mid-position and, using the control 

station press the "Open" button for several seconds and then press the "Stop" button. If 

door did not move in correct direction verify wiring control station. 

Содержание Pro-LT

Страница 1: ...EN Instructions and warnings for installation and use Automation for sectional overhead doors Pro LT...

Страница 2: ...ed at the option of Nice with repaired new or re manufactured parts NICE CANADA will not be responsible for any extra charges incurred in the process of returning defective material All returned mater...

Страница 3: ...OWER SUPPLY AND CONTROL STATION ______________________ CONNECTION OF REVERSING EDGE DEVICE AND CONTROL ACCESSORIES _______ CLUTCH ADJUSTMENT _______________________________________________________ BRA...

Страница 4: ...voltage phase and amperage correspond to available power supply and door application Check that along with your operator you have received the following standard hardware 1 x OPEN CLOSE STOP 3 button...

Страница 5: ...ble for model PRO LTB WIRING TYPE STANDARD C 2 Wiring constant pressure on close momentary contact on open and stop Wired to accept reversing edge radio control photocells loops and OPEN CLOSE devices...

Страница 6: ...ing Outdoor external devices should have security features to prevent unauthorized operation ofthe door Never cross under a moving door Press the OPEN device or activate quick release disconnect devic...

Страница 7: ...t be properly installed and working smoothly Remove all door locks prior to installation I Install control station away from all moving door parts within sight ofthe door and a minimum of 5 ft 1 5 m f...

Страница 8: ...to operator frame using four 3 8 x bolts and 3 8 serrated hex nuts provided TRACKSPACER CARRIAGEASSEMBLY TOWARDS OOOR HEX NUT 3 8 16UNC LOCK WASHER 3 8 TOWARDS OPERATOR TAKE UP BOLT 3 8 16UNC HEX NUT...

Страница 9: ...ine drawn earlier CARPENTER S LEVEL WALl 3 Mount a wood block or angle iron to the wall above the door opening as shown below The wall mounting bracket has 3 holes for anchoring to wood block or angle...

Страница 10: ...carriage spring pin by pulling on rope When installed the open side of notch should face the door 2 Using 3 8 bolts and nuts provided align the mounting holes of straight arm and curved arm so that pi...

Страница 11: ...LLY DISCONNECTED To adjust door travel 1 Open cycle Depress cam plate and spin Open limit cam away from Open limit switch to increase door travel or spin Open limit cam towards the Open limit switch t...

Страница 12: ...INSIDE CONTROL BOX POWER WlRING Use 1 1 8 2 85 cm diameter holes for all power wiring Connect single phase power supply to terminals L line and N neutral on three pole power terminal strip 0 1 PHASE...

Страница 13: ...External interlock tenninals 0 3 RADIII Dfl1III 1tif 4 Single button open close device Wire to terminals 7 and 8 on control terminal strip 5 Wire to terminals 3 and 6 on control Loop detectors photoce...

Страница 14: ...is de energized Wben solenoid is energized brake shoes should release from drum with sufficient clearance to avoid contact between shoes and drum To adjust brake tension tighten to increase or loosen...

Страница 15: ...ISK OF INJURY OR DEA TH DO NOT ATTEMPT TO USE EMERGENCY DISCONNECT I SYSTEM WHILE OPERATOR IS RUNNNG TO AVOID BEING STRUCK BY DOOR ARM DO NOT STAND DIRECTLY UNDER THE RELEASE ARM WHEN PULLING THE RELE...

Страница 16: ...hes if necessary 3 Verify and adjust clutch and brake Do not lubricate 4 Lubricate chains bearings and limit shaft 5 Verify that motor and operator runs smoothly and quietly Verify that carriage runs...

Страница 17: ...08 c s I D J DATE I APPROVED I DRAIJN BY UNLESS THER IISE SPECIFIED DIMENSI NS ARE IN INCHES TOLERANCES XX 01 ANGLES 30 REVISION A TITLE LIMITED DUTY OPERATOR PRO LT LTB WEIGHT lb I SIZE B I PAGE 1 1...

Страница 18: ...D HEX NUT 3 32UNF tl R irfRaNAf 37 PncH oRtrrE c rvl oFFsErLINK I coNN L NK EYWAY r 4 SO x 1 1 4 LG aFfuFN 3r16 x1 tc LoNG L MfiEDDUTYFRAMESUPPoRTI BR4q EII4 J H oirFD SELF RouNohicWAstsER HEAD scRFWr...

Страница 19: ...CLOSE THE DOOR PHASE PRo LT GJ l 2HP 110 MSLT GJ WW REV F I DATE 29 01 07 TECH HELP LINE CANADA H877l 888 1116 ll ll 1 888 816 8584 IF MOMENTARY OPERATION ON CLOSE 92 WIRING IS DESIRED THEN RE INSTAL...

Страница 20: ...C Canada H9P 2T5 Tel 514 822 1116 Toll Free 877 888 1116 CHICAGO 721 W Racquet Club Dr Addison IL USA 60101 Tel 630 501 1909 Toll Free 844 542 9025 ATLANTA 2885 N Berkeley Lake Rd Suite 7 Duluth GA US...