have any doubts regarding the loop you have made, measure inductance before
proceeding, as de scribed in section “6 – Simulations and checks”. The loop is cor-
rect if inductance is between 80 and 300 µH.
04.
To protect the loop against mechanical stress, it may be useful to insert a cord of
string or plastic in the groove. Seal the groove with bitumen or resin for outdoor use.
Pay attention to sealant temperature: it must not exceed the maximum temperature
for the electrical wire in the loop, which is normally 70°C.
05.
Fig. 6
shows the correct loop composition.
4
–
PROGRAMMING
The programs described in this section refer to the LP1 with one loop. On the LP2 pro-
gramming of the second loop is available in sequence after the first loop.
Programming takes place using key
P1
(
Mode
) which allows you to scroll through the
various functions available (on the LP2, first those for loop 1 and then those for loop 2).
Once you have reached a function, you may use
P2
(
Level
) to choose the “value” to be
assigned to the function. Both lists of functions and values are “circular lists”; when the
list reaches its end, it starts scrolling from the beginning again.
TABLE 1
Loop Number of turns to
circumference make with the wire
Less than 3 m Request calculation
3-6 m 5
6-10 m 4
10-25 m 3
More than 25 m 2
(size best avoided)