3.1 - Programming procedure and Operation Test
01.
First program the infrared detector with 1 alarm pulse:
dip-switch 3 = OFF
(
Table 1
).
02.
Then program the PIR infrared detector sensitivity:
dip-
switch 2
with the minimum required value (
Table 1
).
03.
Set the “delay after intrusion” to the minimum value:
trimmer PT2
(
fig. 7
).
04.
Set the microwave detector sensitivity value (
trimmer
PT1 - fig. 7
).
05.
Check coverage of the protected area: make a number
of brief movements within the area and check the signals
emitted by the led. If necessary, adjust the sensitivity val-
ue.
Caution!
– The infrared sensor lens is fixed on the
cover and therefore the detection tests must be per-
formed with the device closed.
06.
After adjusting sensitivity, to reduce the risk of improper
alarms, set
dip-switch 3 to ON
(2 pulses for alarm).
07.
For the same reason, set the “delay after intrusion” to the
maximum value.
trimmer PT2
(
fig. 7
), according to
detection requirements.
08.
After testing operation, set
dip-switch 4 to ON
to switch
off the led signals.
Table 1
Dip Switch
Function
Notes
Dip 1
Not used
Dip 2 = OFF
Infrared sensor sensitive area up to 6 m
Dip 2 = ON
Infrared sensor sensitive area up to 12 m
Dip 3 = OFF
N° infrared pulses for alarm = 1
Dip 3 = ON
N° infrared pulses for alarm = 2
12345678910
11
12
0
1
2
3
4
4
3
2
1
m