![Nice HSCU1 Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/nice/hscu1/hscu1_instructions-and-warnings-for-installation-and-use_1686682027.webp)
MENU 3
Message
N° 1
N° 2
N° 3
N° 4
N° 5
N° 6
Type of alarm associated in factory
ALARM GROUP A,B,C
: this regards all indoor and outdoor intruder detectors – example of message: “Warning: robbery alarm at home
of Rossi, via Pascoli 10 Rome”; (the specific detector that tripped the alarm is then specified).
TAMPERING ALARM
: all tamper-proof devices can trip this alarm – example of message: “Warning: tamper alarm at home of Rossi, via
Pascoli 10 Rome”; (the specific detector that tripped the alarm is then specified).
PANIC ALARM
: alarm activated manually by the user via transmitter or keypad – example of message: “Warning: danger at home of
Rossi, via Pascoli 10 Rome”; (the name of the person who activated the alarm is then specified).
ROBBERY ALARM (or distress)
: alarm activated manually by the user via transmitter or keypad – example of message: “Warning:
request for first aid at home of Rossi, via Pascoli 10 Rome”; (the name of the person who activated the alarm is then specified).
TECHNOLOGICAL ALARM
: alarm activated by technical sensors (smoke, flooding, and others) – example of message: “Warning:
flooding alarm signal at home of Rossi, via Pascoli 10 Rome”; (the specific detector that tripped the alarm is then specified).
LOW BATTERY ALARM
signal to indicate low battery charge on one of the system devices – example of message: “Warning: low bat-
tery on system of Rossi, via Pascoli 10 Rome”; the device with the low battery is then specified.
DIRECT ACCESS
Enables (yes) or disables (no) the option for direct access from this number; i.e. the possibility of calling the control panel from a
mobile phone and enable operations without entry of the user code as the caller ID is recognised automatically by the system.
Notes for recording numbers in the phone book.
•
Telephone line check
: the control panel normally listens for the free PSTN line tone before making the call. If the line is disturbed, the control panel may not
detect a free line. Therefore, to cancel this check process, enter the symbol
✱
(press
) in the programming phase as the first digit of the telephone number.
•
Pause between numbers
: if a pause occurs between one number and the next when dialling numbers, enter the symbol
P
(press
) at the point of the pause.
6.2.2 -
MESSAGES
VOCAL MESSAGES
This section enables the recording of vocal alarm messages to be sent to the
respective numbers in the phone book (those associated with the message
during the programming phase) 6 messages are available (plus message N° 7)
for a total recording of max. 240 seconds.
Recording vocal messages
To record the various vocal messages associated with alarm events, proceed
as described below, with reference to
Menu 3
and the following warnings:
•
For messages N° 1 to N° 6.
Each of these messages proposes a specific event as set in the factory (see
Menu 3
). If the association is as required on the user’s system, during the
procedure simply press
OK
to confirm; otherwise refer to the paragraph
“Replacing the vocal event association”.
•
For vocal message N°1 - ALARM GROUP A, B, C.
The message is normally sent in the event of an alarm in any of the system
group zones (A, B, C). However, during the procedure, some of these groups
can be excluded so that the message is not transmitted (for example in the
case of an external alarm).
To exclude a group, press the number corresponding to the group:
1
= group
A,
2
= group B,
3
= group C. Then confirm selection by pressing
OK
. The dis-
play then shows the enabled groups.
Note
- The enable function applies only
to the telephone transmission of the alarm message.
•
For vocal message N° 7.
This message is a reminder which is read by the control panel to the user
when the latter calls the unit. If there are no domotic actuators, the message
can describe normal control operations.
Example of message text:
- to check the control panel status, press:
0
,
#
- to disarm the control panel press:
0
,
✱
,
0
,
#
- for total arming of the control panel, press:
0
,
✱
,
1
,
#
- to activate system groups A and B press:
0
,
✱
,
2
,
#
If remote domotic actuators are envisaged (turning on lights, electrical appli-
ance control etc.) the message must contain information on how to execute
the various commands according to the actuators present (see 9.2.9).
Vocal message recording procedure:
01.
From the menu MESSAGES press
OK
to confirm: VOCAL MESSAGES is
displayed.
02.
Press
OK
again to confirm: VOCAL MESSAGE N°1 is displayed.
03.
Select the required message using keys
and
and press
OK
to con-
firm. The text
O
K
TO RECORD is displayed.
04.
Press and hold
OK
and start to record the message. During recording, the
remaining recording time is displayed.
05.
At the end of recording, release
OK
. The control panel automatically
replays the message.
06.
If required, listen to the message again by pressing
OK.
07.
If recording is successful, press
ESC
to confirm the recorded message and
exit the procedure.
08.
If the recording is not satisfactory, press C to cancel and repeat the proce-
dure.
This procedure can be used to record, re-listen to and modify the various mes-
sages.
Replacing the vocal event association
A vocal massage can be associated with a different event from that set in the factory.
During the message configuration phase, when the default associated event is proposed, simply select a different one using keys
and
.
As well as the 6 proposed events, other events can be programmed if required (see
Menu 4
).
MENU 4
MAINS FAILURE
(models HSCU1GC and HSCU1C only): the call is made after a programmable interval (see SETTINGS) of mains failure to the control panel
from the electrical mains – example of message “Warning: power failure at home of Rossi, via Pascoli 10 Rome”
PERIODIC CALL
: the call is made after a programmable number of hours (see SETTINGS) to confirm correct operation of the control panel – example of
message “Alarm system operation OK at home of Rossi, via Pascoli 10 Rome”
TEMPERATURE
: the call is made when the control panel temperature exceeds 70°C or falls below 5°C – example of message: “Warning: abnormal temper-
ature at home of Rossi, via Pascoli 10 Rome”
Special event alarm
( display _ _ _ _ _ / _ _ _ _ _ ). A special alarm can be programmed to generate a call when a special event occurs.
Possible events are:
ALL allarm
OPEN
door left open
SIM expiry warning message (programmed expiry, see SET-
TINGS)
SIM VALIDITY
10
8
25
Содержание HSCU1
Страница 1: ...Nice HSCU1 Instructions and warnings for installation and use Home security control unit 0682 ...
Страница 2: ......
Страница 14: ...12 b a 11 12 13 CRACK CRACK CRACK 14 x 3 x 1 a 15 ...
Страница 15: ...18 only for models HSCU1G and HSCU1 x 4 19 x 3 a 16 x 3 17 13 ...
Страница 32: ...42 x 4 44 only for models HSCU1GC and HSCU1C 43 only for models HSCU1G and HSCU1 30 ...
Страница 39: ......