English –
5
EN
ENGLISH
210
125
310
1
IMPORTANT!
Before performing any type of operation or
procedure, read carefully the general instructions
in this manual (Chapter 7) and the application
limits (paragraph 2.2)
1
PRODUCT DESCRIPTION AND INTENDED USE
NDCC2000 - NDCC2100
are control units intended to be used to automate
rolling shutters and sectional doors with three-phase motors.
NDCC2200
is a control unit intended to be used to automate sectional doors
controlled by a single-phase motor.
Model
Door type
Connection
Max Power
NDCC2000
Sectional Rolling
Shutter
Three-phase
2.2kW
NDCC2100
Sectional Rolling
Shutter
Three-phase with brake
2.2kW
NDCC2200
Sectional
Single phase with
starting capacitor
2.2kW
CAUTION! – All uses other than the intended use described and use
in environmental conditions other than those described in this manual
should be considered improper and forbidden!
All control unit models can be connected to all common safety features. To
open and close a door, you only need to operate the appropriate button
installed on the cover or the external button or via a radio receiver.
CAUTION! – The control units described in this instruction manual can
-
not be used in areas where there are risks of explosion.
2
INSTALLATION
2.1 - Pre-installation checks
Before proceeding with installation, check the condition of the product com-
ponents, suitability of the selected model and conditions of the intended instal-
lation environment:
• Check that all the materials are in good working order and suited to the
intended use.
• Check that all conditions of use fall within the “application limits” of the
product (paragraph 2.2) and the value limits shown in the “Product technical
characteristics”.
• Check that the installation location is compatible with the overall dimensions
of the product (
Fig. 1
).
• Check that the surface chosen for installing the product is solid and can
ensure stable attachment.
• Make sure that the installation area is not subject to flooding; if necessary, the
product may be installed, appropriately raised above ground level.
• Check that the space around the product allows safe and easy access.
• Check that all electrical cables to be used belong to the type listed in Table 1.
• Check that the automation has mechanical stops in both the opening and
closing phases.
2.2 - Product application limits
The product is only to be used as indicated in the following table:
Control unit Control unit power
supply
Type of motor
NDCC2000
NDCC2100
Three-phase 3x400 V AC
– 50/60 Hz
Three-phase 3x400 V AC – 50/60
Hz – with Nice encoder or mechanical
limit switches
NDCC2200
Single-phase 1x230 V AC
– 50/60 Hz
Single-phase 1x230 V AC – 50/60
Hz – with Nice encoder or mechanical
limit switches
(*)
In respect of the corresponding application limits.
CAUTION! – The control units described in this instruction manual
cannot be used in areas where there are risks of explosion.
original operating instructions in Italian
Contents
GENERAL WARNINGS: SAFETY - INSTALLATION - USE
.............................................
3
1 - PRODUCT DESCRIPTION AND INTENDED USE
....................................................
5
2 - INSTALLATION
..........................................................................................................
5
2.1 - Tests prior to installation
.................................................................................................................
5
2.2 - Product application limits
...............................................................................................................
5
2.3 - Typical system
...............................................................................................................................
6
2.4 - Installation of the control unit
.........................................................................................................
6
3 - ELECTRICAL CONNECTIONS
.................................................................................
9
3.1 - Connecting the three-phase power supply cable for NDCC2000 and NDCC2100 control units
.....
9
3.2 - Connecting the single-phase power supply cable for NDCC2200 control units
..............................
9
3.3 - Description of the electrical connections: power supply, safety and control devices,
and accessories ............................................................................................................................
9
3.4 - Electrical connections of the control unit
......................................................................................
10
3.5 - STOP SAFETY EDGE Input
..........................................................................................................
11
3.6 - Connecting a radio receiver
.........................................................................................................
11
3.7 - Initial startup and electrical connections test
................................................................................
11
3.8 - Total deletion of the control unit memory
.....................................................................................
11
3.9 - Recognition of the connected devices and the Opening and Closing positions
............................
12
3.9.1 - Recognition of the Opening and Closing positions with electronic limit switch (encoder)
...........
12
3.9.2 - Recognition of the Opening and Closing positions with mechanical limit switch
........................
13
3.10 - Operating modes
.......................................................................................................................
14
3.11 - Oview programming unit
...........................................................................................................
13
4 - TESTING AND COMMISSIONING
..........................................................................
14
4.1 - Testing
.........................................................................................................................................
14
4.2 - Commissioning
............................................................................................................................
14
5 - FURTHER DETAILS AND DIAGNOSTICS
...............................................................
14
5.1 - Further details
..............................................................................................................................
14
5.1.1 - Signals when switching ON
......................................................................................................
14
5.1.2 - Other functions
.........................................................................................................................
14
5.2 - DIAGNOSTICS
.............................................................................................................................
15
6 - BASIC TROUBLESHOOTING (resolving common problems)
................................
16
7 - PRODUCT DISPOSAL
............................................................................................
16
8 - TECHNICAL SPECIFICATIONS
..............................................................................
17
CE DECLARATION OF CONFORMITY
.........................................................................
18
Содержание D-Pro Action Series
Страница 2: ......