5.1 - Calibration

During calibration process the device learns the position of the Up and Down limit positions. The calibration can be performed automatically or 

manually. During the automatic calibration the motor will perform Up, Down and Up again manoeuvres to recognize the limit positions. During 

the manual calibration limit positions must be saved manually while the motor performs Up/Down manoeuvres.

If the automatic calibration was not able to properly recognize the limit positions, perform the manual calibration instead.

The control unit will calibrate itself after the user performs two full manoeuvres (Up to Down and Down to Up), but performing 

the calibration according to one of the procedures below is recommended before operation.
Before the calibration, set the shutter to the middle position.

To perform automatic calibration, proceed as described below.

Table A8 - Automatic calibration

Example

01.

Press and hold the programming pushbutton (fig. 1).

02.

Release the programming pushbutton (fig. 1) when the LED illuminates with 

blue

 color (3rd position).

  

03.

Press key 

n

 (or second channel) of the transmitter.

04.

The motor will complete Up, Down and Up again maneuvers automatically.

  

  

05.

The programming procedure concludes automatically upon finishing 2 complete maneuvers.

To perform calibration manually, proceed as described below. Perform manual calibration only when automatic doesn’t work.

Table A9 - Manual calibration

Example

01.

Press and hold the programming pushbutton (fig. 1).

02.

Release the programming pushbutton (fig. 1) when the LED illuminates with 

blue

 color (3rd position).

  

03.

Press key 

s

 (or first channel) of the transmitter to start calibration.

04.

Device will start Up maneuver.

05.

Press key 

n

 (or second channel) of the transmitter to set Up limit position.

06.

Device will start Down maneuver.

07.

Press key 

n

 (or second channel) of the transmitter to set Down limit position.

08.

Device will start Up maneuver.

09.

Press key 

n

 (or second channel) of the transmitter to set Up limit position.

10.

The programming procedure concludes automatically

5.2 - Partial positions

The BiDi-Shutter control unit enables setting a quickly accessible partial positions. Partial positions work only with transmitters memorized in 

Mode I. 

Table A11 - Available partial positions

Press at the same time to activate

Default position

1

and 

t

1st and 3rd channel 
S1 and S2

50% of the working time

2

and 

n

 

1st and 2nd channel

15% of the working time

• 

If the Venetian blinds mode is enabled (see chapter 5.5), by default (2nd partial position), the blinds stop at 15% and slats 

are rotated to 10%.

• 

If the Venetian blinds mode is disabled, by default (2nd partial position), the shutter stops at 15%.

• 

In order for the partial positions to work, the calibration must be performed. 

• 

Pressing S1 and S2 at the same time might not be possible for some types of pushbuttons/switches.

Содержание BiDi-Shutter

Страница 1: ...EN Instructions and warnings for installation and use Interior bidirectional interface for tubular motor BiDi Shutter Nice ...

Страница 2: ...awnings rolling shutters Venetian blinds and similar The BiDi Shutter control unit incorporates a radio transceiver that operates at the frequency of 433 92 MHz with rolling code technology to guarantee optimal safety levels Each control unit can memorise up to 30 mono or bidirectional transmitters in the series ERA ERGO FLOR NICEWAY and VERY which enable the remote control of the unit In the 30 t...

Страница 3: ...n connected to S1 is responsible for Up movement and the pushbutton connected to S2 is responsible for Down movement The pushbuttons carry mains voltage and must therefore be adequately protected and insulated 4 MEMORISING TRANSMITTERS This chapter describes the memorisation procedures in Mode I used to control a single automation with the 3 keys of the transmitters and Mode II used to control an ...

Страница 4: ...e LED illuminates with red color 1st position 03 Within 10 seconds Monodirectional transmitters press and hold any key of the transmitter to be memorized for at least 3 seconds Bidirectional transmitters press any key of the transmitter to be memorized MONO 3s BIDI 04 If the memorisation procedure is successful the LED emits 3 red flashes 05 Repeat steps 3 and 4 to acquire all the remotes 06 After...

Страница 5: ...irectional transmitters press and hold the required key of the transmitter to be memo rized for at least 3 seconds Bidirectional transmitters press the required key of the transmitter to be memorized MONO 3s BIDI 06 If the memorisation procedure is successful the LED emits 3 orange flashes 07 Repeat steps 5 and 6 to acquire all the remotes with the same command 08 Repeat steps 3 to 6 to acquire al...

Страница 6: ... as described below Perform manual calibration only when automatic doesn t work Table A9 Manual calibration Example 01 Press and hold the programming pushbutton fig 1 02 Release the programming pushbutton fig 1 when the LED illuminates with blue color 3rd position 03 Press key s or first channel of the transmitter to start calibration 04 Device will start Up maneuver 05 Press key n or second chann...

Страница 7: ...t to the specified position range Table A14 Setting a virtual limit switch Example 01 Bring the shutter blind awning at your desired position virtual limit switch 02 Press and hold the programming pushbutton 03 Release the programming pushbutton when the LED illuminates with blue color 3rd position 04 Press key t or third channel of the transmitter If the LED will confirm with one blue flash the p...

Страница 8: ... as described below Table A16 Setting Venetian blinds behavior Example 01 Press and hold the programming pushbutton fig 1 02 Release the programming pushbutton fig 1 when the LED illuminates with cyan color 7th position 03 Press key s or first channel of the transmitter toggle the setting the LED informs about current setting Fixed cyan Venetian blinds control enabled Turned off Venetian blinds co...

Страница 9: ...to confirm the correct removal 05 After 10 seconds that the device doesn t receive any signal the programming procedure concludes auto matically 5 8 Factory reset If the control unit needs to be reset to the factory settings all transmitters and setting will be deleted proceed as described below Table A20 Restoring to factory defaults Example 01 Press and hold the programming pushbutton fig 1 02 R...

Страница 10: ...0 including climatic sensors Transceiver range Estimated at 150 m in open space and 20 m inside buildings Max transmit power 10 dBm The transceiver range is strongly influenced by other devices operating at the same frequency with continuous transmission such as alarms and radio headphones which interfere with the control unit transceiver 8 PRODUCT DISPOSAL This product is an integral part of the ...

Страница 11: ...www niceforyou com Nice SpA Oderzo TV Italia info niceforyou com code ...

Отзывы: