15.1 - Outputs
Figure 16 - BOARD OUTPUTS
Commercial Gate Operator Accessory Outputs:
OUT1 and OUT2:
Individual, isolated relays provide COMMON, NORMALLY
OPEN, and NORMALLY CLOSED dry contacts for switching accessories
based on programming of the “Auxiliary IO” function. These outputs are
programmed in the “FUNCTION Auxiliary I/O” menu.
Magnetic Lock:
Provides fused power (1.85A max) and isolated relay
COMMON, NORMALLY OPEN, and NORMALLY CLOSED dry contacts for
electrically powered and maintained magnetic locks. The delay for magnetic
lock activation/deactivation may be adjusted from 0 to 5 seconds.
Lamp:
Provides fused power (1.85A max) to drive a flashing warning lamp
to indicate gate operation. This output is active when the gate is operating
(Opening and Closing). Sets the amount of time the lamp accessory output is
activated prior to gate movement. Settings from 0 to 5 seconds with a step
of 0.5 seconds.
Alarm:
Provides fused power (0.5A @ 12VDC) to drive an alarm siren to signal
the occurrence of a hard shutdown, caused by 2 consecutive entrapment
events (signals). This alarm output is reset by pressing the “Reset Hard
Shutdown” button on the front panel or activating the “FIRE” input.
15.2 - Inputs
Figure 17 - INPUTS
GATE OPERATOR ACCESSORY INPUTS:
Auxiliary Inputs 1 (16), 2 (18):
These digital inputs may be connected to
the digital outputs of accessories and programmed to activate or control
the gate operator in a number of different modes. Shorting the pins through
a dry contact activates the programmed settings for these inputs. These
inputs are programmed in the “FUNCTION Auxiliary I/O” menu.
SAFETY Input:
(22) Dry contact input that can be programmed for an
inductive loop or photo-eye detector. Shorting the Safety Input (22) to
GND reverses a closing gate to the full open position. The opened gate is
held opened for as long as the input is active. This input is not for external
entrapment sensors.
SHADOW Input:
(24) Dry contact input that can be programmed for an
inductive loop or photo-eye detector. Shorting the Shadow Input (24) to
GND maintains an OPEN gate fully open and a CLOSED gate fully closed
until deactivated.
Setting the Shadow Input to “Photo Mode” causes the opening gate to stop,
then reopens the gate when the Shadow Input is deactivated.
ENTRAP Input:
(26) Dry contact input that can be programmed for an
inductive safety loop or photo-eye detector. Shorting the ENTRAP input (26)
to GND while the gate is opening cause the gate to close to the fully closed
position. This input is not for external entrapment sensors.
EDGE Input:
(28) This input may be configured as “DIGITAL” or “ANALOG”
as required by the sensor type. When configured as “DIGITAL”, this is a dry
contact input; otherwise when configured as “ANALOG”, , additional options
are available to declare if the edge is protecting the open or close direction,
and the input must measure 8.2K - 10K. When the input is activated it stops
the gate regardless of direction of travel, momentarily reverses it then stops.
EXIT Input:
(30) Dry contact input for a vehicle exit sensor. Shorting the
EXIT input to GND opens gate from the closed position and holds gate open
with maintained input or reverses gate if closing.
FIRE Input:
(32) Dry contact input for a fire department control switch.
Shorting the Fire input (32) to GND opens the gate and holds the gate open
until the control switch is deactivated. This input is “hold to run”. Auto-close
is disabled when this input is activated. Also clears hard shutdown.
GUARD STATION
Guard Station OPEN:
(34) Dry contact input for a guard station open
switch. Momentarily shorting the Open input (34) to GND opens the gate to
the full open position with the subsequent auto-close feature enabled.
Guard Station STOP:
(35) Dry contact input (Normally Closed) for a guard
station stop switch. Momentarily opening the Stop input (35) stops the
opening gate at its current position. While this input is activated, all other
inputs are disabled and are not functional.
Guard Station CLOSE:
(36) Dry contact input for a guard station close
switch. Momentarily shorting the Close input (36) to GND closes the gate
(master and slave).
RADIO
Radio Open:
(39) Dry contact input for an accessory radio open switch.
Momentarily shorting the Open input (39) to GND opens the gate to the full
open position with the subsequent auto-close feature enabled.
Radio Close:
(40) Dry contact input for an accessory radio close switch.
Momentarily shorting the Close input (40) to GND closes the gate.
Radio Input:
Open/Close: (39 and 40) If you tie open and close together the
unit will operate as a Step by Step command each time the input is shorted
to GND, it will either OPEN, STOP or CLOSE.
Safety
Shadow
Entrap
Shadow
Safety
Shadow
Entrap
Shadow
15 - ACCESSORY INPUTS AND OUTPUTS