19
14 - LEARNING MODE
NICE has taken great care to simplify the installation, operation and safety of this device and to ensure longevity and reliability
of the unit over time. The learning procedure consists of the following steps shown below:
NOTE:
The control board is already in the “LEARNING MODE” when shipped.
NOTE:
The learn process will not initiate until the minimum number of external entrapment sensors are connected. One in
the open direction and one in the close direction
If the board is not in “LEARN MODE”, press:
FUNCTION
OK
SWING
OK
LIGHT
OK
AVERAGE
HEAVY
You are in LEARN MODE if “ENTER” is flashing.
1.
Test the motor direction by pressing and holding CLOSE. If the gate OPENS, swap the RED and BLACK motor leads
and retest to verify correct operation. Set limits according to the operators installation manual.
Limits and motor
direction MUST be set prior to learning the board!
2.
Press and hold the OPEN or CLOSE button on the gate controller until the gate is 50% open.
3.
Press OK to allow the control board to scan for the required monitored entrapment devices. If they are not present,
“BLUEBUS ERROR” will be displayed and start the learning sequence. The gate will open partially then stop. This is being
done, so that the control board can sense the type and operational condition of the drive motor. The gate will then run
to the closing limit (one leaf at a time in case of dual application: “slave” closes first then “master” follows), so that it can
properly sense the close limit switch. The gate will then fully open to test the open limit switch then fully close at high
speed. The gate should be fully learned by the control board at this point.
The gate opener is now programmed for basic usage.
Safety
Shadow
Entrap
Shadow
FUNCTION BUTTON
UP SELECTION
ARROW
OK BUTTON
DOWN SELECTION
ARROW
Содержание Apollo 4300SW
Страница 2: ......
Страница 40: ...38 35 GATE ARM INSTALLATION Figure 33 CORRECT LAYOUT INCORRECT INSTALLATION Figure 34...
Страница 44: ......