Adjusting the Gate Speed
The gate speed can be increased or decreased a
from the operator’s default speed.
To adjust the gate speed, take the following steps
1.
At a gate status display, press the MENU button
twice. The CLOSE TIMER display appears.
2.
Simultaneously, press the OPEN and RESET
buttons to enter the Installer Menu. Release
the buttons and the LEARN LIMITS display
appears. It is the first item in the Installer Menu.
3.
Press NEXT until the OPEN SPEED (or CLOSE
SPEED) display appears. The factory default
setting is 5. A speed setting of 1 slows
the gate travel speed to open or close in
approximately 15 seconds. A speed setting of
10 increases gate travel and opens or closes in
approximately 10 seconds.
4.
Use the SELECT and NEXT buttons to navigate
and change the speed setting on the display.
5.
To exit the Installer Menu, press the MENU
button. The gate status appears in the display
indicating you have returned to Run Mode.
NOTICE
Two options, one for OPEN SPEED the other
for CLOSE SPEED, appear in the Installer
Menu. The steps involved in changing the
open speed are shown below. The steps to set
the close speed are the same, you just need
to access the CLOSE SPEED option.
DISPLAY AND MENU OPTIONS
Figure 41. Adjusting Gate Speed
CT 0 (OFF)
CLOSE TIMER
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
HYSECURITY
GATE CLOSED
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
1. Start at a gate
status display.
2. To access the
User Menu,
press the MENU
button twice.
3. Access the
Installer Menu, by
simultaneously,
pressing the
OPEN and
RESET
buttons.
4. Use NEXT to
navigate to the
menu display.
Change the
setting using the
SELECT and
NEXT buttons.
OS 5
OPEN SPEED
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
LL 0 (OFF)
LEARN LIMIT
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT