CONNECTING DC POWER
To connect the DC power:
1.
Turn off the DC and AC power switches.
2.
Slide the plastic cover off the control box.
3.
Attach the red spade connector to the battery
terminal on the DC power switch. See
Figure 20. Connecting DC Power
NOTICE
For extended battery backup installation, refer
"Installing the Extended Battery Backup
POWER
USING A SOLAR POWERED OPERATOR
HySecurity offers a solar version of the SwingSmart
operator: SwingSmart DCS20. The solar model
has different internal wiring and includes software
programmed for solar use. The Smart DC
Controller has a built-in charger which allows a 24V
solar panel (or two 12V panels) a direct connection
to the SwingSmart operator with no additional
electronic devices required.
To plan a solar-powered site, read through this
entire section. Keep in mind that the SwingSmart
DCS 20 operator does not have the following
components:
z
Transformer
z
AC power supply board
z
AC service outlet
z
Various wiring adaptations that are standard in
a SwingSmart DC 20 operator
NOTICE
Solar panels are NOT included in the purchase
of the SwingSmart DCS 20 Solar operator. Also,
adapting a standard SwingSmart DC operator
to a solar application is not recommended. For
ease of installation and proper functionality,
be sure to order a SwingSmart DCS 20 for a
solar-powered site.