![Nice HySecurity SwingSmart DC Series Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/nice-hysecurity/swingsmart-dc-series/swingsmart-dc-series_installation-and-programming-manual_1687275026.webp)
INSTALLATION
ADJUSTING THE LIMIT SWITCHES
1.
Determine whether the gate operator is a
). Stand on the secure side
of the gate. If the gate opens to the right, it is
a right-hand operator.
Figure 11. Right Hand Dual Gate Opening
Figure 12. Left Hand Dual Gate Opening
PUBLIC SIDE
SECURE SIDE
Right Hand OPEN
Left Hand OPEN
PUBLIC SIDE
SECURE SIDE
NOTICE
For a right-hand operator, the OPEN switch is
the left limit switch as shown in
opposite occurs in a left-hand operator; the
OPEN switch becomes the right limit switch.
2.
To adjust the limit cams, use a Phillips-head
screwdriver and loosen the fastener that
secures each limit cam to the limit plate.
3.
Manually, open and close the gate. Move
the limit cams so they trip the appropriate
limit switch at the full OPEN and full CLOSE
positions.
4.
Secure the limit cams by retightening the two
Phillips head screws.
A fin on the limit plate fits into the taper clamp.
This feature ensures the limits always track the
gate arm position even if the gate is struck and
the taper clamp slips.
Figure 13. Limit Switches
NOTICE
When reassembling the taper clamp, make
sure the limit plate fin is seated into the slot
on the taper clamp.
LIMIT PLATE
LIMIT CAM
LOOSEN
SCREWS
LIMIT
CAM
LIMIT
SWITCHES
SwingSmart DC Programming and Operations
MX3640-01 Rev. E ©2020
26