31
11.5 - Function (Continued)
Advance Settings:
The following settings are available for customizing the gate operator as required by the custom-
er’s installation requirements:
Set Language (English, Spanish, Italian)
Set clock 12H/24H
Set LCD Contrast
Direction of the Motor (only selectable in learning mode)
Auto Close Opt. (ON - Gate only closes when at open limit, OFF - Gate auto-closes from any
open position)
Exit Opt. (ON - Free Exit always opens gate, OFF - Free Exit doesn't open gate if stopped
while opening)
Set Anti-tailgate (Closes gate immediately after vehicle has cleared safety sensors)
Phototest (activates monitoring feature for BlueBus photoeyes)
Select inputs LOOP or PHOTO
Select UL/EDGE input type (NO, NC, Analog)
Select Master / Slave Motor1 or Motor2
Activate link for remote Master/Slave (Enables control of an additional gate operator board -
Not Applicable in this installation)
Power Fail Open (Opens gate automatically on batter backup power if main AC power input
loss is detected) (Not Applicable in this installation)
Motor 12V (Forces motor control voltage to +12VDC even if the supply voltage varies from
+9.5VDC up to +35VDC)
Set Virtual Encoder (Used for motors without built-in encoders)
Default:
This setting gives the installer/user the option of returning some or all
settings of the gate operator to the original factory settings:
• System settings
• Radio Channel settings
• Event settings
• Charger settings
ESC:
Exit the FUNCTION menu.