11
1.5 - Connect power cable and attach indi-
vidual wires (Continued)
Using a small flathead screwdriver, turn each of the
screws indicated in a counter clock direction to open
each of the wires terminals. Strip 1/4” of the end of
the 18AWG conductors with wire strippers to avoid
nicking the standard wire. Insert the stripped ends of
the conductors as shown in Figure 10 T5 MOTOR
WIRING for the T5. Insert the stripped end of the
conductors as shown in Figure 11 T7 MOTOR
WRING for the T7.
Re-tighten the wire terminals to complete the wiring
connections to the T5/T7. Re-attach the cover and
secure with the provided Phillips-head screws
1 - T5ETL-1K AND T7ETL-1K OPERATOR INSTALLATION (Continued)
Figure 11 - T7 MOTOR WIRING
Figure 10 - T5 MOTOR WIRING
Note:
Terminate the other end of the T5/T7
motor control cable shown in Figure 12
T5/T7 WIRING DIAGRAM and Figure 13
T5/T7 MOTOR WIRING DIAGRAM.