Adjustments
Push Buttons
TIMER TO CLOSE
Adjusts time before gate automatically closes
Adjustable 5 to 70 seconds.
DUAL GATE DELAY
Adjusts delay between master and slave
(Dual board only)
operation 0-4 seconds (836 only with
magnetic, solenoid, and other locking
devices)
CURRENT SENSITIVITY
Increases or decreases the Auto Reverse
sensitivity.
LED ENABLE
When depressed, activates LEDs for 15
minutes to assist in installation and troubleshooting.
Hold the push button down for five seconds to put
the board in program mode.
RESET
Resets the microprocessor. Returns processor to
last known state.
Jumpers
STOP CIRCUIT JUMPER
When the STOP CIRCUIT
JUMPER is connected, the gate
will operate normally.
STOP CIRCUIT JUMPER
When a 3-button station is connected
to the board, the STOP CIRCUIT
JUMPER must be removed.
OPERATE
When depressed, activates the gate. Used for initial
installation and testing.
Hard Shutdown Reset
Resets the operator when the gate current
senses twice before fully opening or closing.