background image

23

10.1 - PARTS IDENTIFICATION

Control Box 

#CBOX1K

Chassis

#CHBOX350

Arm Assembly

#ABOX350

10 - 35001K & 36001K INSTALLATION

35001K & 36001K INST

ALLA

TION

Содержание CBOX1K

Страница 1: ...Nice Apollo Control Box Vehicular Gate Operator Control Revision 1 0 0 0_6 2014 CBOX1K...

Страница 2: ......

Страница 3: ...ion 18 9 3 Push to open installation 19 9 4 Actuator mounting 19 9 5 Actuator wiring 20 9 6 Gate bracket mounting 20 9 7 Limit motor connection to the board 21 9 8 Limit switch adjustment 21 9 9 Setti...

Страница 4: ...ction Dry contact inputs are provided for loop probe and photoelectric detectors as well as edge sensors guard station and fire department control of gate opening and closing Voltage outputs 12VDC and...

Страница 5: ...he moving gate system No entry into the gate is ever authorized and should be prevented by whatever measures are required for that specific installation Care should always be used during installation...

Страница 6: ...nal gate types 4 3 15 Any existing manual gate latches shall be removed or disabled when an automatic gate system is installed Use only mag locks controlled by the system 3 3 Gate system safety device...

Страница 7: ...nt any device that operates the gate opener where the user can reach around over or through the gate to operate the controls Controls should be mounted at minimum 8 feet away from any moving part of t...

Страница 8: ...ontrol board for STANDBY operation See section 16 for information on STANDBY mode Battery Connect wires to the battery terminal block The positive wire of the battery connects to the left terminal mar...

Страница 9: ...included The CBOX1K control box is used for many different model operators The following pages show installation guides for these models Refer to the correct model operator section for instructions on...

Страница 10: ...IDENTIFICATION Control Box 11111B T5 Actuator NT TO5012 T7 Actuator NT TO7012 Operator QTY QTY QTY QTY QTY QTY T5ETL 1K 1 1 1 1 0 1 T7ETL 1K 1 0 1 1 1 1 8 NT T51K NT T71K INSTALLATION NT T51K NT T71K...

Страница 11: ...the rear pivot bracket using the T5 or T7 graph provided on the next pages The graphs serve to establish the dimensions A and B and the value of the maximum opening degree of the gate Important The va...

Страница 12: ...5 16 6 11 16 7 1 16 7 1 2 7 7 8 8 1 4 8 11 16 9 1 16 9 7 16 9 13 16 10 1 4 10 5 8 11 7 16 11 3 15 16 4 5 16 4 3 4 5 1 8 5 1 2 11 13 16 12 3 16 12 5 8 13 13 3 8 Recommended installation line NOT RECOM...

Страница 13: ...1 7 16 11 13 16 5 5 16 6 5 16 6 11 16 7 1 16 7 1 2 7 7 8 8 1 4 8 11 16 9 1 16 9 7 16 9 13 16 10 1 4 10 5 8 11 7 16 11 NOT RECOMMENDED VALUES AREA Recommended installation line C 4 1 2 3 1 2 5 1 8 6 6...

Страница 14: ...of the T5 T7 to the attachment bracket using the supplied bolt and washer with a 13mm metric socket as shown Be careful not to over tighten the bolt 2 3 1 Unlock the strain relief bushing located on t...

Страница 15: ...2 into the connection labeled Motor 2 Note Motor 1 Make sure motor lead connector is plugged in below the limit 5 pin terminal connector T5 and T7 Limit and Encoder wiring T5 and T7 Motor wiring green...

Страница 16: ...e RED and BLACK motor leads Using the OPEN button on the front of the Control board hold the button down until the gate reaches the fully intended open position Adjust the Open Limit Switch until the...

Страница 17: ...x 11111B 816 Actuator with 8 harness 816X Actuator with 38 harness Supplied with 16501K Pivot Arm 1116 2 with 16501K Gate attach bracket 10025215 2 with 16501K Bolt kit 2 with 16501K 9 15501K 16501K I...

Страница 18: ...rate of speed of the gate it is critical that the measurements below are followed The pivot arm may need to be cut to achieve the correct placement of the actuator mounting hole Measurements are take...

Страница 19: ...g hole Measurements are taken from the center of pivot of the gate hinge Vertical position of pivot arm DIRECTION OF OPENING GATES CLOSED HINGE POST HINGE POST LEFT HAND SWING RIGHT HAND SWING TOP VIE...

Страница 20: ...n below These connections enable the Apollo 816 limit switch and smart sensor inputs into the gate controller 816 limit switch and smart sensor wiring Connect the Apollo 816 actuator cable to the 5 pi...

Страница 21: ...pin connector for motor 1 into the connection labeled Motor 1 on the controller as shown For a dual gate installation install the 5 and 3 pin and connector for motor 2 into the connection labeled Mot...

Страница 22: ...te limit wires CLOSE LIMIT Red CLOSE LED 3 Using the CLOSE button on the front of the Control Board hold the button down until the gate reaches the fully intended closed position 4 Adjust the Closed L...

Страница 23: ...23 10 1 PARTS IDENTIFICATION Control Box CBOX1K Chassis CHBOX350 Arm Assembly ABOX350 10 35001K 36001K INSTALLATION 35001K 36001K INSTALLATION...

Страница 24: ...istances are from the hinges square to the center of the mounting post Longer gates should operate at slower speeds E C B D A OPTIMUM SETTING SHOWN IN GREEN A Open Degrees B Inches C Inches D Inches E...

Страница 25: ...the gate in the closed position and level for proper operation 3 Conduit should be considered at this time for cable routing from the control box to the chassis assembly Welding mounting bracket Weld...

Страница 26: ...to the primary arm using a 1 2 x 2 1 4 hex bolt brass washers and lock nut The stop tab should be positioned away from the gate Install the aluminum adjustable arm to the secondary arm using the 1 2...

Страница 27: ...te attach bracket to the gate Note Permanent welds or bolt attachment should be completed once limits are set Make sure that the primary arm is locked into the stop tab on the secondary arm Located in...

Страница 28: ...wiring White Close limit Orange Open Limit Green Limit Common Green Orange White 1 2 3 4 5 3500 3600 Limit Wiring White Close limit Orange Open Limit Green Limit Common Green Orange White 1 2 3 3500...

Страница 29: ...N limit switch is now set Note if red LED illuminates reverse orange and white limit wires CLOSE LIMIT Red CLOSE LED 3 Using the CLOSE button on the front of the Control Board hold the button down unt...

Страница 30: ...irection MUST be set prior to learning the board 2 Press and hold the Open or Close button on the gate controller until the gate is 50 open 3 Press ENTER to allow the control board to scan for attache...

Страница 31: ...ars hard shutdown GUARD STATION Guard Station Open 34 Dry contact input for a guard station open switch Momentarily shorting the digital input to GND opens the gate to the full open position with the...

Страница 32: ...cting other assigned remote controls This procedure needs to be performed at the Nice Plug In Receiver with the affected Nice remote control 1 Press and hold the button on the side of the Nice receive...

Страница 33: ...for the operator connection The wire table is based on stranded copper wire Wire run calculations are based on a 110 VAC power source with a 3 voltage drop on the power line plus an additional 10 red...

Страница 34: ...g edge of the closing gate The EXIT sensor input is provided to activate to open the gate or re open a closing gate upon sensing an exiting vehicle Figure FIRE DEPT INPUT 15 2 Magnetic lock connection...

Страница 35: ...ty equipment and connections Clean equipment and connections 16 6 Improper broken inadequately supported equipment wiring and conduit loose connections of terminals and loose ferrules 16 7 Poor mechan...

Страница 36: ...lls Figure LAYOUT FOR IN GROUND LOOPS Entrapment Protection Inputs Typical Installation Diagram Utilizing Photocells Figure LAYOUT FOR PHOTOCELLS Loop Safety Loop Safety Loop Shadow Loop Exit 4 Min fr...

Страница 37: ...at the control panel before making any electric service power connection Be aware of all moving parts and avoid close proximity to any pinch points Know how to operate the manual release Adjust the un...

Страница 38: ...Stop gate movement Close the gate Figure GENERAL BOARD OVERVIEW THE PROGRAMMING BUTTONS INDICATED IN THE ABOVE REFERENCE SHOULD BE USED ONLY AFTER UNDERSTANDING THE MANUAL AND ITS RELATION TO THE PROG...

Страница 39: ...itivity of sudden impact force to the moving gate on a scale of 1 to 10 1 being most sensitive ESC Exit the FORCE menu 20 2 Speed Max Sets the limit of maximum allowed gate speed on a scale of 20 to 1...

Страница 40: ...dvance Settings The following settings are available for customizing the gate operator as required by the customer s installation requirements Set Language English Spanish French Set clock 12H 24H Set...

Страница 41: ...perator or system intended for use in a commercial location or building such as a multi family housing unit five or more single family units hotels garages retail store or other building servicing the...

Страница 42: ...Table 3 SYMPTOM S POSSIBLE SOLUTION Check that power to the circuit board is turned ON Check terminal block wiring for loose or broken wires If voltage measures OK check the terminal block Check the...

Страница 43: ...43 1 1 2 2 A A B B COMPANY NICE APOLLO NAME CONTROL BOX GENERAL OVERVIEW 18 22 18 18 8 32...

Страница 44: ...LE POLE 1115 1 4 SWITCH PUSH BUTTON CNTRL BOX 1119 1 5 1050 CIRCUIT BOARD 1050 1 6 1050 BOARD MOUNT KIT 10055090 1 7 NICE RECEIVER 318NPI 1 8 1 1 2 2 A A B B TITLE Company 2 6 8 3 7 4 5 1 Note Control...

Страница 45: ...the information from the dated proof of purchase receipt to confirm the warranty period or the technician will confirm your extended warranty period through your registration information on file The t...

Страница 46: ...e and has tested the gate to make sure that the gate stops and reverses a short distance with minimal resistance applied Approximately 40 lbs on a swing gate at the end of the gate 8 The installer has...

Страница 47: ...47...

Страница 48: ...Contact us Nice Group USA Inc 12625 Wetmore Road Suite 218 San Antonio TX 78247 Ph 1 210 545 2900 Fax 1 210 545 2915 www niceapollo com www facebook com NiceApollo...

Отзывы: