background image

8

5 - CIRCUIT BOARD LAYOUT 

6 - PARTS IDENTIFICATION

Accessory

Output

Connections

Power Input

Connections

Motor Output

Connections

BlueBus

Connection

Master / Slave

Connection

Accessory Input Connections

Control Box 

#11111B

816 - Actuator with 8’ harness

816X - Actuator with 38’ harness

(Supplied with 16501K)

Pivot Arm #1116

(2 with 16501K)

Gate attach bracket 

#10025215

(2 with 16501K)

Bolt kit

(2 with 16501K)

Earth Ground

Содержание 15501K

Страница 1: ...Nice Apollo Swing Gate Opener Vehicular Swing Gate Operator Revision 1 0 0 0_2 2014 Model 15501K Model 16501K...

Страница 2: ......

Страница 3: ...BRACKET MOUNTING 12 14 LIMIT AND MOTOR CONNECTION TO THE BOARD 13 15 LIMIT SWITCH ADJUSTMENT 13 16 SETTING LIMIT SWITCHES 14 17 LEARNING MODE 15 18 ACCESSORY INPUTS AND OUTPUTS 16 18 1 Outputs 16 18...

Страница 4: ...ction Dry contact inputs are provided for loop probe and photoelectric detectors as well as edge sensors guard station and fire department control of gate opening and closing Voltage outputs 12VDC and...

Страница 5: ...he moving gate system No entry into the gate is ever authorized and should be prevented by whatever measures are required for that specific installation Care should always be used during installation...

Страница 6: ...nal gate types 4 3 15 Any existing manual gate latches shall be removed or disabled when an automatic gate system is installed Use only mag locks controlled by the system 3 3 Gate system safety device...

Страница 7: ...t any device that operates the gate opener where the user can reach around over or through the gate to operate the controls Controls should be mounted at minimum 8 feet away from any moving part of th...

Страница 8: ...Motor Output Connections BlueBus Connection Master Slave Connection Accessory Input Connections Control Box 11111B 816 Actuator with 8 harness 816X Actuator with 38 harness Supplied with 16501K Pivot...

Страница 9: ...geometry and rate of speed of the gate it is critical that the measurements below are followed The pivot arm may need to be cut to achieve the correct placement of the actuator mounting hole Measureme...

Страница 10: ...tuator mounting hole Measurements are taken from the center of pivot of the gate hinge 8 2 Vertical position of pivot arm DIRECTION OF OPENING GATES CLOSED HINGE POST HINGE POST LEFT HAND SWING RIGHT...

Страница 11: ...wards a red LED will illuminate below the terminal If solar power is to be used it will be necessary to program control board for STANDBY operation See section 16 for information on STANDBY mode Batte...

Страница 12: ...as shown below These connections enable the Apollo 816 limit switch and smart sensor inputs into the gate controller 816 limit switch and smart sensor wiring Connect the Apollo 816 actuator cable to...

Страница 13: ...l the 5 and 3 pin connector for motor 1 into the connection labeled Motor 1 on the controller as shown For a dual gate installation install the 5 and 3 pin and connector for motor 2 into the connectio...

Страница 14: ...range and white limit wires CLOSE LIMIT Red CLOSE LED 3 Using the CLOSE button on the front of the Control Board hold the button down until the gate reaches the fully intended closed position 4 Adjust...

Страница 15: ...irection MUST be set prior to learning the board 2 Press and hold the Open or Close button on the gate controller until the gate is 50 open 3 Press ENTER to allow the control board to scan for attache...

Страница 16: ...ars hard shutdown GUARD STATION Guard Station Open 34 Dry contact input for a guard station open switch Momentarily shorting the digital input to GND opens the gate to the full open position with the...

Страница 17: ...cting other assigned remote controls This procedure needs to be performed at the Nice Plug In Receiver with the affected Nice remote control 1 Press and hold the button on the side of the Nice receive...

Страница 18: ...for the operator connection The wire table is based on stranded copper wire Wire run calculations are based on a 110 VAC power source with a 3 voltage drop on the power line plus an additional 10 red...

Страница 19: ...g edge of the closing gate The EXIT sensor input is provided to activate to open the gate or re open a closing gate upon sensing an exiting vehicle Figure FIRE DEPT INPUT 21 2 Magnetic lock connection...

Страница 20: ...ty equipment and connections Clean equipment and connections 22 6 Improper broken inadequately supported equipment wiring and conduit loose connections of terminals and loose ferrules 22 7 Poor mechan...

Страница 21: ...Photocells Figure LAYOUT FOR IN GROUND LOOPS Entrapment Protection Inputs Typical Installation Diagram Utilizing Photocells Figure LAYOUT FOR PHOTOCELLS Loop Safety Loop Safety Loop Shadow Loop Exit...

Страница 22: ...at the control panel before making any electric service power connection Be aware of all moving parts and avoid close proximity to any pinch points Know how to operate the manual release Adjust the un...

Страница 23: ...Stop gate movement Close the gate Figure GENERAL BOARD OVERVIEW THE PROGRAMMING BUTTONS INDICATED IN THE ABOVE REFERENCE SHOULD BE USED ONLY AFTER UNDERSTANDING THE MANUAL AND ITS RELATION TO THE PROG...

Страница 24: ...itivity of sudden impact force to the moving gate on a scale of 1 to 10 1 being most sensitive ESC Exit the FORCE menu 26 2 Speed Max Sets the limit of maximum allowed gate speed on a scale of 20 to 1...

Страница 25: ...dvance Settings The following settings are available for customizing the gate operator as required by the customer s installation requirements Set Language English Spanish French Set clock 12H 24H Set...

Страница 26: ...perator or system intended for use in a commercial location or building such as a multi family housing unit five or more single family units hotels garages retail store or other building servicing the...

Страница 27: ...Table 3 SYMPTOM S POSSIBLE SOLUTION Check that power to the circuit board is turned ON Check terminal block wiring for loose or broken wires If voltage measures OK check the terminal block Check the...

Страница 28: ...28 1 1 2 2 A A B B COMPANY NICE APOLLO NAME CONTROL BOX GENERAL OVERVIEW 18 22 18 18 8 32...

Страница 29: ...29 1 1 2 2 A A B B COMPANY NICE APOLLO NAME ACTUATOR GENERAL VIEW 43 17 ACTUATOR CLOSED 7 38 5 74 31 41 4 0 3 0 1 66 7 01...

Страница 30: ...LE POLE 1115 1 4 SWITCH PUSH BUTTON CNTRL BOX 1119 1 5 1050 CIRCUIT BOARD 1050 1 6 1050 BOARD MOUNT KIT 10055090 1 7 NICE RECEIVER 318NPI 1 8 1 1 2 2 A A B B TITLE Company 2 6 8 3 7 4 5 1 Note Control...

Страница 31: ...SPUR GEAR A2017 1 3 LIMIT SCREW A2019 1 4 LIMIT TOWER BUSHING A2009 1 5 MAIN SCREW A2018 1 6 SEAL HOUSING ALUMINIUM A2064 1 7 BEARINGS A2087 1 8 COVER TUBE A2091 1 9 AC GEAR NUT A2006 1 10 SEAL A2025...

Страница 32: ...A2012K 1 7 LIMIT CAP SEAL A2010 2 8 STRAIN RELIEF A2029 1 9 SMART SENSOR 816 Only A2072 1 10 HARNESS See Note 1 11 1 1 2 2 A A B B Company NICE APOLLO Description Actuator Back Housing 7 8 11 9 1 10...

Страница 33: ...the information from the dated proof of purchase receipt to confirm the warranty period or the technician will confirm your extended warranty period through your registration information on file The t...

Страница 34: ...34...

Страница 35: ...bstruction sensing feature and has tested the gate to make sure that the gate stops and reverses a short distance with minimal resistance applied Approximately 40 lbs on a swing gate at the end of the...

Страница 36: ...Contact us Nice Group USA Inc 12625 Wetmore Road Suite 218 San Antonio TX 78247 Ph 1 210 545 2900 Fax 1 210 545 2915 www niceapollo com www facebook com NiceApollo...

Отзывы: