Transport
VVM 500 should be transported and stored vertically in a
dry place.
However, the VVM 500 can be carefully laid on its back when
being moved into a building.
R
0
R
0
Assembly
•
Place VVM 500 on a solid foundation indoors that can take
its weight.
Use the product’s adjustable feet to attain a horizontal
and stable set-up.
30 - 50 mm
30 - 50 mm
15 - 40 mm
20-55 mm
•
The space where VVM 500 is located must be frost-free.
•
Because water can exit the safety valve
1
for hot water,
when connected to VVM 500, the space where VVM 500
is placed must be provided with a floor drain.
1 Not enclosed.
INSTALLATION AREA
Leave a free space of 800 mm in front of the product. All
service on VVM 500 can be carried out from the front.
800
10-25
50
50
NOTE
Leave 10 – 25 mm free space between VVM 500
and the wall behind for routing cables and pipes.
7
Chapter 2 | Delivery and handling
NIBE VVM 500
Delivery and handling