Technical specifications
3 x 400 V
Electrical data
9
kW
Additional power
400 V 3N~50 Hz
Rated voltage
16.2
A
Max operating current
16
A
Fuse
3 – 76
W
Output, Heating medium pump
3 – 76
W
Output, charge pump
IP21
Enclosure class
Heating medium circuit
low energy
Energy class circ-pump
low energy
Energy class charge pump
0.3 (3 bar)
MPa
Max system pressure heating medium
500
l/h
Min flow
70
°C
Max HM temp
Pipe connections
int.
G25
Heating medium, CU pipe
ext.
G25
Hot water connection
int.
G25
Cold water connection
int.
G25
Heat pump connections
Miscellaneous
Indoor module
22.8
l
Volume hot water coil
500
l
Volume, total indoor module
80
l
Volume buffer vessel
2
l
Volume, solar coil
1.0
MPa
Cut-off pressure, hot water coil
(10 bar)
0.3 (3 bar)
MPa
Max permitted pressure in indoor module
Capacity hot water heating According to EN 16147
390
litre
Amount of hot water (40 °C)*
Dimensions and weight
760
mm
Width
900
mm
Depth
1,900
mm
Height
2,000
mm
Required ceiling height
240
kg
Weight (excl packaging)
Part no.
069 400
Part no.
*Applies in the case of normal comfort mode, tap flow 8 litres/minute and incoming cold water 10 °C. Increased hot water comfort can be obtained at lower