Nibe VEDEX 3300 Скачать руководство пользователя страница 8

6

VEDEX 3300

For Home Owners

För konsumentbroschyr

Förvärmd

primärluft

Termisk

returanslutning

Sekundärluft

Ställbara

luftventiler

Värmeupp–

tagande flänsar 

med turbulatorer

Returanslutning

Askrumslucka

med inspektionsglas

Keramikroster

Ventil för 

primärluft

Påfyllningslucka

Primärluft

Styrpanel

Vattenkyld botten

Flambalja för 

slutförbränning

Hetvattenretur

Hetvattenuttag

Rökgasstyrd sugfläkt

Kylslinga

Settings, instructions and maintenance

General instructions

The way the wood is chopped, its type and moisture con-
tent are all determining factors that affect the function 
and efficiency of the boiler.
Adjust the size of the wood to fit the hearth. Suitable 
length of chopped wood for VEDEX 3300 is 0.5m.
The wood is placed on the ceramic grate.
The combustion process works by reverse combustion 
where the combustion gases are forced down through the 
grate by an induction fan. The fan is controlled by the flue 
gas temperature. A damper ensures that a self induced 
draught does not occur when the fan is off.
The fan works at two speeds which means that the high-
est speed occurs when adding wood and normal speed 
during operation.
A tilting smoke stop prevents blow back.

 
Always use dry wood. Wood with a high moisture content 
reduces the combustion temperature and causes increased 
amounts of environmentally harmful emissions as well as 
reducing efficiency.
Extremely dry wood can cause a large fire which can 
create large amounts of gas. In addition, there is a risk 
of flashover, which in turn causes irregular combustion. 
Carpentry off cuts can be used but should be mixed with 
other wood. All wood over 10 cm must be chopped. Only 
use untreated and clean wood.
Combustible gases are created as the wood heats up. 
These burn at temperatures between 300 - 900°C. The 
gases make up 75% of the wood’s energy content, the 
rest is in the created charcoal, which also eventually burns.
Final combustion occurs in the compartment under the 
grate after the supply of secondary air.

Primary air control

The control damper on the front of the boiler is used to 
distribute the air supply to the hearth.

In the left position the air supply is from the top of the 

 

combustion chamber.
In the right-hand position, the air supply is from the 

 

lower part just above the ceramic grate in the hearth.
In the central position the air is distributed equally from 

 

both inlets.

  Flue gas thermostat 

 This thermostat senses the flue gas tempera-
ture. When the temperature has been reached 
and the filler door closed, the fan resumes 
normal speed. When firing is ended and the 
flue gas temperature has dropped, the fan is 
stopped by the thermostat. 

Max. thermostat 

 This thermostat stops the fan when the boiler 
water temperature is too high. 

Charge thermostat

 This thermostat starts the charge pump at the 
set boiler water temperature.
Before adding the first pieces of wood, check 

that the boiler and the heating system are filled with wa-
ter, and that the flue gas thermometer is installed in the 
flue pipe. Then make settings as follows.

Set the flue gas thermostat to position:

 

Set the max. thermostat to 90 °C.

 

Set the charge thermostat to 70 °C.

 

 Adjust the primary air damper as follows.

 

1  Hard and mixed wood

 

Adjust the damper to the right.

2  Softwood

 

Adjust the damper to the left.

For a newly installed boiler, new adjustments should be 
made if combustion is not efficient and poor or if another 
type of wood is used. Also see section “Wood firing”.

20

100

40

80

60

0

120

2

1

bar

3

0

4

2

1

bar

3

0

4

T

G

20

100

40

80

60

°

C

0

120

T

G

1

0

R

VEDEX  3000

°

C

°

C

°

C

20

30

40

70

80

90

50

60

°

C

20

30

40

70

80

80

90

50

60

P

P

Boiler default settings

The instrument panel contains three thermostats.

115,0

164,0

267,6

327,0

208,0

345,3

369,5

375,0

48,0

5,5

11,0

11,0

10,5

79,4

107,2

157,0

97,8

23,2

Ø 52,8

53,5

3 st hål ø36

Hål ø6

Hål 11,5x29

Hål

Hål

20

100

40

80

60

0

120

2

1

bar

3

0

4

20

100

40

80

60

0

120

2

1

bar

3

0

4

OLD

115,0

164,0

267,6

327,0

208,0

345,3

369,5

375,0

48,0

5,5

11,0

11,0

10,5

79,4

107,2

157,0

97,8

23,2

Ø 52,8

53,5

3 st hål ø36

Hål ø6

Hål 11,5x29

Hål

Hål

20

100

40

80

60

0

120

2

1

bar

3

0

4

20

100

40

80

60

0

120

2

1

bar

3

0

4

OLD

115,0

164,0

267,6

327,0

208,0

345,3

369,5

375,0

48,0

5,5

11,0

11,0

10,5

79,4

107,2

157,0

97,8

23,2

Ø 52,8

53,5

3 st hål ø36

Hål ø6

Hål 11,5x29

Hål

Hål

20

100

40

80

60

0

120

2

1

bar

3

0

4

20

100

40

80

60

0

120

2

1

bar

3

0

4

OLD

115,0

164,0

267,6

327,0

208,0

345,3

369,5

375,0

48,0

5,5

11,0

11,0

10,5

79,4

107,2

157,0

97,8

23,2

Ø 52,8

53,5

3 st hål ø36

Hål ø6

Hål 11,5x29

Hål

Hål

20

100

40

80

60

0

120

2

1

bar

3

0

4

20

100

40

80

60

0

120

2

1

bar

3

0

4

OLD

Höger

Vänster

Содержание VEDEX 3300

Страница 1: ...MOS GB 0733 1 VEDEX 3300 M10528 INSTALLATION AND MAINTENANCE INSTRUCTIONS VEDEX 3300 LEK...

Страница 2: ......

Страница 3: ...__________________________ 9 Pipe installation Connection_ ______________________________________ 10 Flue gas thermometer______________________________ 10 Filling_ ____________________________________...

Страница 4: ...bers in brackets refer to the section Component locations The boiler is designed for houses with water borne heating and is environmentally approved for accumulator tank firing This appliance is not i...

Страница 5: ...of wa ter heater size or the length of coil Abbreviations HW Hot water CW Cold water S V Safety valve AV Shut off valve WH Water heater EX Expansion vessel SV1 Shunt valve SV2 Mixer valve CP1 Charge p...

Страница 6: ...stops the fan when the boiler temperature exceeds the set value Charge thermostat Thisthermostat starts and stops the charge pump at the set value 20 100 40 80 60 0 120 2 1 bar 3 0 4 Indicator lamp f...

Страница 7: ...door 66 pulling up the turbulator and brushing clean This should be done a few times between chimney sweep visits For optimum combustion and efficiency the boiler s sec ondary combustion chamber shou...

Страница 8: ...fter the supply of secondary air Primary air control The control damper on the front of the boiler is used to distribute the air supply to the hearth In the left position the air supply is from the to...

Страница 9: ...of wood are used stack these over the grate hole to wards the rear wall When the wood in the boiler has been burned and the flue gas temperature drops to 80 85 C and a mini mal bed of embers remains...

Страница 10: ...take must be as large as the smoke pipe duct Chimney VEDEX 3300 has a vertical flue pipe connection with an external diameter of 133 mm Angled flue pipe supplied as standard Different chimney heights...

Страница 11: ...amic grate Place the ceramic inserts in through the filler door First position the front stone B Then position the rear stones C and D followed by stones E and F Flame trough Open the combustion chamb...

Страница 12: ...e component parts Note Flue gas thermometer VEDEX 3300 is supplied with an enclosed flue gas ther mometer which must be installed in the flue gas door outlet Filling Fill the boiler with water using a...

Страница 13: ...the electrical panel for this type of docking See Electrical installation Reconnection When the boiler s temperature and flue gas temperature exceeds the set temperature on the relevant thermostat th...

Страница 14: ...nnection also the charge pump Electrical circuit diagram Electrical installation Laddpump Max thermostat 3 only controls the boiler s fan and charge thermostat 19 only controls the external charge pum...

Страница 15: ...070 590 85 20 40 1115 1150 170 R32 inv 125 159 inv R25 inv R32 inv 15 utv R25 inv 15 utv 370 450 R25 inv min 250 515 180 125 1275 Minsta avst nd till v gg 250 mm 125 70 1320 Technical specifications T...

Страница 16: ...specifications 45 42 40 3 36 19 2 Component location boiler section Component location front panel 133 utv R25 inv 15 utv R25 inv 125 45 19 3 42 40 2 36 83 22 22 66 96 83 66 96 33 81 82 33 81 82 100...

Страница 17: ...3 Front panel 36 Indicator lamp operation 40 Thermometer 42 Manometer 45 Control switch 64 Sight glass 65 Filler door 66 Soot door for convection part 68 Combustion door 81 Flow line R32 int 82 Expans...

Страница 18: ...cessories LEK LEK LEK Charger pack 1 Part no 089 872 Contents 1 x non return valve connection 25 1 x charge pump 6 mvp with shutoff valves 1 x shunt valve for heating system connection 25 1 x circulat...

Страница 19: ...ler water volume 65 litres Voltage 230 V Average output during wood firing 33 kW Wood magazine volume 95 litres Wood magazine width 300 mm Wood magazine depth 550 mm Filler door width 300 mm Filler do...

Страница 20: ...wice a year for optimum function and a long serv ice life Check that the boiler is off and that no embers are in the combustion chamber Disconnect the fan from the electrical socket on the boiler Remo...

Страница 21: ...into the flue gas fan when sweeping use the supplied cover plate as follows Remove the soot door Insert the cover plate over the hole as illustrated Reinstall the soot door to prevent soot exiting wh...

Страница 22: ...20 VEDEX 3300...

Страница 23: ......

Страница 24: ...STAD NB Tel 0168 477722 Fax 0168 476998 E mail info nibenl nl www nibenl nl V lund Varmeteknik Filial af NIBE AB Brog rdsvej 7 6920 Videb k Tel 97 17 20 33 Fax 97 17 29 33 E mail info volundvt dk www...

Отзывы: