2. Pre-installing the support stand
The stand is pre-installed and delivered folded. The illustration
shows the stand in the installed position. The stands should
be prepared before mounting on the roof.
71
4,0
0
47
2,0
0
59
0,0
0
14
,0
0
14,00
For other pitches (less than 45°) the support rail on the rear
side must be shortened.
45° = standard length (742 mm combined length, 714 mm
cc drill holes)
35° = 590 mm cc drill holes
25° = 472 mm cc drill holes
Drill diameter: 9 mm
In all cases, the edge distance is 14 mm to the side and up-
ward. The support rails must be shortened after drilling accord-
ing to the dimensions in the illustration.
SOLAR FP215 P/PL
Chapter 4 |
Mounting
38