![Nibe FLM S45 Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/nibe/flm-s45/flm-s45_installer-manual_1686195027.webp)
Clean the filter in FLM S45 regularly; how often depends
on the amount of dust in the ventilation air.
Set the interval for the reminder to clean the filter in this
menu.
The menu shows the time remaining until the next re-
minder, and you can also reset active reminders.
MENU 1.2.2 - NIGHT COOLING
Start temperature, exhaust air
Setting range: 20 – 30 °C
Lowest diff., outdoor/exhaust air
Setting range: 3 – 10 °C
Activate night cooling here.
When the temperature in the house is high and the
outdoor temperature is lower, a cooling effect can be
obtained by forcing the ventilation.
If the temperature difference is greater than the set
value for “Min diff outdoor and exhaust air”, and the
exhaust air temperature is higher than the set value for
“Start temperature exhaust air”, the ventilation operates
at speed 4 until one of these conditions is no longer
valid.
Caution
Night cooling is only activated when heating is
not permitted.
MENU 7.4 - SELECTABLE IN/OUTPUTS
Here you select the room sensor for FLM cooling
(AZ10-BT50) on the relevant AUX input.
MENU 1.2.3 - FLM COOLING
Room set point value
Setting range: 5 – 40 °C
Cooling at room over temp
Setting range: 1 – 10 °C
When you have activated FLM cooling in menu 7.2.2,
set the desired room temperature in this menu. You
also select the temperature at which cooling will start.
FLM cooling starts when the room temperature exceeds
the set
Room set point value
+
Cooling at room over
temp
.
FLM cooling stops when the room temperature falls
below
Room set point value
.
In systems with several FLM, settings can be made for
each FLM unit.