Installation alternative
ANOTHER HEAT PUMP
When FLM S45 is installed together with another heat
pump, the brine circuit is supplied with a trim valve
(RN1). This is necessary for adjusting the brine flow.
FLM COOLING
Where cooling is prioritised, FLM S45 can be installed
in the brine circuit after the heat pump in the direction
of flow.
FLM cooling Requires an external fan (GQ4), four
dampers that are controlled by two motors (QM40),
(QM41) and a non-return damper (RM2). A room sensor
(AZ10-BT50) is also required in one of the rooms where
cooling is required. For electrical connection, see page
The external fan (GQ4) takes over ventilation, which is
led out of the house without recovery. At the same time,
FLM S45 circulates air to and from other rooms where
cooling is required, normally two to three bedrooms.
Bedroom
Hall
Kitchen/
bathroom/
WC
QM41
QM40
GQ4
RM2
Normal operation.
Bedroom
Hall
Kitchen/
bathroom/
WC
QM41
QM40
GQ4
RM2
NIBE FLM S45
Chapter 4 | Pipe and ventilation connections
16