Maintenance routines
5
For Home Owners
FLM 30
Check that there is water in the water seal (92) to the
drip-pan (93). If the water seal is empty or has a very
low water level so that it “gurgles” water can be filled,
for example, using a watering can through the drip-
pan water hose which then forms a water seal or di-
rectly in the drip-pan (the inner cover plate must then
be dismantled). The water seal is maintained during
filling.
After using for a period of time dust and other particles
can clog the water seal, consequently, you should
check this regularly and clean when necessary.
The ventilation devices in the house should be
cleaned regularly to maintain the correct ventilation.
The device settings must not be changed.
NOTE! If you take down more than one ventilation de-
vice for cleaning, do not mix them up.
Cleaning the ventilation devices
Checking the condensation
water seal
LEK