A H E A D O F T H E F L O W
®
www.nibco.com
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455
www.nibco.com
6
®
4.5 Position OPEN Target Plates (8) so they are in the full upward position for “left-hand” (counter-clockwise) opening valves.
Secure OPEN Target Plates (8) by tightening Screws (37a). See Fig. 6.
4.6 Determine the number of turns required to fully open the valve. See Table 1 for NIBCO valves. You should always confirm
actual turns required to open the valve by counting them.
4.7 Using Table 6, choose the closest “Number of Turns to Open Valve” and the corresponding “Distance Between Targets”
dimension “X”.
4.8 Measure and position both SHUT Target Plates (9) at dimension “X” from OPEN Target Plates (8). See Fig. 6.
4.9 Secure both SHUT Target Plates (9) by tightening Screws (37a) with an Allen wrench.
NUMBER
OF TURNS
TO OPEN
VALVE
DISTANCE
BETWEEN TARGETS
X
INCH
MM
10
0.000
0.0
11
0.050
1.3
12
0.150
3.8
13
0.250
6.4
14
0.350
8.9
15
0.450
11.4
16
0.550
14.0
17
0.650
16.5
18
0.750
19.1
19
0.850
21.6
20
0.950
24.1
21
1.050
26.7
22
1.150
29.2
23
1.250
31.8
NUMBER
OF TURNS
TO OPEN
VALVE
DISTANCE
BETWEEN TARGETS
X
INCH
MM
24
1.350
34.3
25
1.450
36.8
26
1.550
39.4
27
1.650
41.9
28
1.750
44.5
29
1.850
47.0
30
1.950
49.5
31
2.050
52.1
32
2.150
54.6
33
2.250
57.2
34
2.350
59.7
35
2.450
62.2
36
2.550
64.8
37
2.650
67.3
NUMBER
OF TURNS
TO OPEN
VALVE
DISTANCE
BETWEEN TARGETS
X
INCH
MM
38
2.750
69.9
39
2.850
72.4
40
2.950
74.9
41
3.050
77.5
42
3.150
80.0
43
3.250
82.6
44
3.350
85.1
45
3.450
87.6
46
3.550
90.2
47
3.650
92.7
48
3.750
95.3
49
3.850
97.8
50
3.950
100.3
51
4.050
102.9
ADJUSTMENT OF TARGET PLATES
Table 4