NI WSN-3214 User Guide and Specifications
30
ni.com
Note
Use the
Node Properties
dialog box in the LabVIEW Project Explorer window to change the
DIO settings.
The NI WSN-3214 device has two bi-directional digital I/O channels. Each channel supports
eight operational modes depending on whether the channel is configured as digital output or digital
input. The NI-WSN software controls the different modes of operation by turning on and off the high
side and low side switches.
Digital Output Operational Modes
The channels support the following digital output operational modes:
•
•
•
3V TTL Logic (Open-Collector with Pull-Up)
•
Drive High and Low (Sinking and Sourcing)
Note
When configured in a digital output mode, reading the channel returns the state of the pin
voltage with TTL thresholds.
Digital Input Operational Modes
The channels support the following digital input operational modes:
•
•
24 V Sinking with Power Management
•
•
Figure 29.
Simplified Circuit Diagram of One DIO Channel
DIO PWR
High
S
ide
S
witch
TTL
P
u
ll Up
DIO
x
3
V
DGND
Low
S
ide
S
witch
DI
(Intern
a
l)
NI W
S
N-
3
214
24 V
S
inking Lo
a
d