Condition/State
LED 1
LED 2
Open session on hardware, port is missing power
Solid red
Off
Hardware is communicating
Solid green Activity green (returns to
idle/off one second after last
TX or RX)
TRC-8546 Specifications
The following specifications are typical for the range -40 °C to 70 °C unless otherwise
noted.
LIN Characteristics
Transceiver
NXP TJA1028
Max certified baud rate
20 kbps
LIN bus lines voltage
-40 VDC to +40 VDC
Supply voltage range (V
SUP
) +8 VDC to +18 VDC normal operating; -0.3 VDC to +40 VDC absolute
limits
MTBF
Contact NI for Bellcore MTBF specifications at other temperatures or
MIL-HDBK-217F specifications.
Power Requirements
Thermal dissipation (at 70 °C)
650 mW max (active mode); 330 mW typical (active
mode)
Power consumption from NI-XNET
Transceiver Cable host
330 mW max (active mode); 150 mW typical (active
mode)
Power consumption from V
SUP
320 mW max; 180 mW typical
Physical Characteristics
To clean the TRC-8546, wipe it with a dry towel.