background image

Notice

 Clean the hardware with a soft, nonmetallic brush. Make sure that

the hardware is completely dry and free from contaminants before

returning it to service.

Mounting Holes

You can mount the SCB-8, either vertically or horizontally, on a DIN rail in an

industrial environment.
You can purchase a compatible DIN rail kit from NI using the part number

781740-01.
The SCB-8 also has two screw holes for a generic wall mount. These wall mount

holes are designed for use with a #4 or #6 panhead screw with a minimum length of

15.88 mm (0.625 in.).

Figure 5. SCB-8 Mounting Screw Holes

2

2

63.5 mm (2.5 in.)

1

1. DIN rail mounting screw holes
2. Wall mounting screw holes

Specifications

© National Instruments

7

SCB-8 Features

Содержание SCB-8

Страница 1: ...SCB 8 Features 2022 07 11...

Страница 2: ...Kit Contents 3 Other Equipment 4 Getting Started With the SCB 8 4 SCB 8 Interior 4 Connecting the SCB 8 5 Mounting Holes 7 Specifications 7 Physical Characteristics 7 Environment 10 Compliance and Ce...

Страница 3: ...Instruments hardware Caution The protection provided by this product may be impaired if it is used in a manner not described in this document Figure 1 SCB 8 Connector Block 1 2 2 1 SCB 8 2 Cover Screw...

Страница 4: ...e Molex Nano Pitch I O connector OCuLink x4 1 m cable NI part number 785486 01 Note Using an OCuLink x4 cable supplied by another manufacturer is not recommended Phillips 1 screwdriver 0 125 in flathe...

Страница 5: ...stall your NI hardware in a chassis Refer to the hardware documentation for your product s for installation instructions 1 Remove the four cover screws with a Phillips 1 screwdriver and open the top c...

Страница 6: ...Remove the protective plastic cover from the Nano Pitch I O connector on the SCB 8 if present and connect the OCuLink x4 cable to the connector 5 Slide the included cable retention bracket around the...

Страница 7: ...industrial environment You can purchase a compatible DIN rail kit from NI using the part number 781740 01 The SCB 8 also has two screw holes for a generic wall mount These wall mount holes are design...

Страница 8: ...B20 B21 Reserved GND MGT Rx 0 MGT Rx 0 GND MGT Rx 1 MGT Rx 1 GND DIO 4 DIO 5 GND MGT REF DIO 0 MGT REF DIO 1 GND MGT Rx 2 MGT Rx 2 GND MGT Rx 3 MGT Rx 3 GND 5 0 V 5 0 V GND MGT Tx 0 MGT Tx 0 GND MGT T...

Страница 9: ...ND GND A15 MGT Rx 2 No Connection A16 MGT Rx 2 No Connection A17 GND GND A18 MGT Rx 3 No Connection A19 MGT Rx 3 No Connection A20 GND GND A21 5 0 V 5 0 V Output B1 5 0 V 5 0 V Output B2 GND GND B3 MG...

Страница 10: ...d MGT Tx n are connected on the SCB 8 Table 1 OCuLink x4 to 0 1 Inch Header Connector Signal Mapping Environment Maximum altitude 2 000 m 800 mbar at 25 C ambient temperature Pollution Degree 2 Indoor...

Страница 11: ...mers For additional environmental information refer to the Engineering a Healthy Planet web page at ni com environment This page contains the environmental regulations and directives with which NI com...

Страница 12: ...to learn about NI service offerings such as calibration options repair and replacement Visit ni com register to register your NI product Product registration facilitates technical support and ensures...