Figure 2. Kit Contents for the SCB-8

3

2

1

1. SCB-8
2. Cable Retention Bracket
3. SCB-8 User Guide

Other Equipment

There are several items not included in your SCB-8 kit that you need to operate the

SCB-8.

Required Items

NI hardware with compatible Molex Nano-Pitch I/O connector

OCuLink x4, 1 m cable (NI part number 785486-01)

Note

 Using an OCuLink x4 cable supplied by another manufacturer

is not recommended.

Phillips #1 screwdriver

 0.125 in. flathead screwdriver

Visit 

ni.com

 for more information about these additional items.

Optional Items

Shielded, multiconductor cable with 14–30 AWG wire

16 position 0.1 inch dual row header

Wire cutters

Wire insulation stripper

ni.com

4

SCB-8 Features

Содержание SCB-8

Страница 1: ...SCB 8 Features 2022 07 11...

Страница 2: ...Kit Contents 3 Other Equipment 4 Getting Started With the SCB 8 4 SCB 8 Interior 4 Connecting the SCB 8 5 Mounting Holes 7 Specifications 7 Physical Characteristics 7 Environment 10 Compliance and Ce...

Страница 3: ...Instruments hardware Caution The protection provided by this product may be impaired if it is used in a manner not described in this document Figure 1 SCB 8 Connector Block 1 2 2 1 SCB 8 2 Cover Screw...

Страница 4: ...e Molex Nano Pitch I O connector OCuLink x4 1 m cable NI part number 785486 01 Note Using an OCuLink x4 cable supplied by another manufacturer is not recommended Phillips 1 screwdriver 0 125 in flathe...

Страница 5: ...stall your NI hardware in a chassis Refer to the hardware documentation for your product s for installation instructions 1 Remove the four cover screws with a Phillips 1 screwdriver and open the top c...

Страница 6: ...Remove the protective plastic cover from the Nano Pitch I O connector on the SCB 8 if present and connect the OCuLink x4 cable to the connector 5 Slide the included cable retention bracket around the...

Страница 7: ...industrial environment You can purchase a compatible DIN rail kit from NI using the part number 781740 01 The SCB 8 also has two screw holes for a generic wall mount These wall mount holes are design...

Страница 8: ...B20 B21 Reserved GND MGT Rx 0 MGT Rx 0 GND MGT Rx 1 MGT Rx 1 GND DIO 4 DIO 5 GND MGT REF DIO 0 MGT REF DIO 1 GND MGT Rx 2 MGT Rx 2 GND MGT Rx 3 MGT Rx 3 GND 5 0 V 5 0 V GND MGT Tx 0 MGT Tx 0 GND MGT T...

Страница 9: ...ND GND A15 MGT Rx 2 No Connection A16 MGT Rx 2 No Connection A17 GND GND A18 MGT Rx 3 No Connection A19 MGT Rx 3 No Connection A20 GND GND A21 5 0 V 5 0 V Output B1 5 0 V 5 0 V Output B2 GND GND B3 MG...

Страница 10: ...d MGT Tx n are connected on the SCB 8 Table 1 OCuLink x4 to 0 1 Inch Header Connector Signal Mapping Environment Maximum altitude 2 000 m 800 mbar at 25 C ambient temperature Pollution Degree 2 Indoor...

Страница 11: ...mers For additional environmental information refer to the Engineering a Healthy Planet web page at ni com environment This page contains the environmental regulations and directives with which NI com...

Страница 12: ...to learn about NI service offerings such as calibration options repair and replacement Visit ni com register to register your NI product Product registration facilitates technical support and ensures...

Отзывы: