NI PXIe-1435 Скачать руководство пользователя страница 2

NI PXIe-1435 User Guide and Specifications

The NI PXIe-1435 (NI 1435) is a PXI Express (PXIe) image acquisition device that supports Base, 
Medium, Full, and Extended Full configuration Camera Link cameras and supports Power over Camera 
Link (PoCL). This document describes how to install and configure the necessary hardware and 
software components to begin using the NI 1435.

Required Components

The following items are necessary to set up and use the NI 1435:

NI 1435 image acquisition device

Camera Link camera

Camera Link cables

One SDR Camera Link cable for Base configuration cameras

Two SDR Camera Link cables of the same length for Medium, Full, or Extended Full 
configuration cameras

National Instruments recommends that you use the following cables to connect your camera:

MDR to SDR Camera Link cable (part number 199745A-05)

SDR to SDR Camera Link cable (part number 199746A-05)

Note

To ensure the high-speed signaling of the Camera Link interface, National Instruments 

recommends that you purchase a Camera Link cable rather than build a custom cable.

One of the following system considerations:

PXI Express/CompactPCI Express chassis with a PXI Express/CompactPCI Express 
embedded controller

MXI kit and a PC running Microsoft Windows 7 (32-bit and 64-bit versions)/Vista (32-bit and 
64-bit versions)/XP SP2 (32-bit)/Server 2008 R2/Server 2003 R2 (32-bit)

NI-IMAQ 4.6 or later driver software, which is included with NI Vision Acquisition Software

Optional software for developing machine vision applications:

NI Vision Builder for Automated Inspection

NI Vision Development Module, which requires one of the following application development 
environments:

LabVIEW

LabWindows

/CVI

Microsoft Visual Studio

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Содержание PXIe-1435

Страница 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Страница 2: ...nk cable part number 199745A 05 SDR to SDR Camera Link cable part number 199746A 05 Note To ensure the high speed signaling of the Camera Link interface National Instruments recommends that you purcha...

Страница 3: ...ations Pollution consists of any foreign matter solid liquid or gas that may reduce dielectric strength or surface resistivity The following is a description of pollution degrees Pollution Degree 1 No...

Страница 4: ...t install the application software and device driver National Instruments provides two options for developing machine vision applications NI Vision Builder for Automated Inspection Vision Builder AI I...

Страница 5: ...ule Refer to the NI Vision Development Module Readme on the NI Vision Development Module installation media for system requirements and installation instructions Documentation for the NI Vision Develo...

Страница 6: ...era Link cable to the Camera Link connector on the NI 1435 front panel 10 Plug in and power on the PXI Express chassis Confirm the Device is Recognized To confirm that the device is recognized complet...

Страница 7: ...shows the connectors Figure 2 NI 1435 Connectors 1 Base Camera Link SDR Connector 2 Medium Full Camera Link SDR Connector 3 Digital I O Connector NI PXIe 1435 Image Acquisition CAMERA LINK BASE 1 3 2...

Страница 8: ...iguration chip for Camera Link communication between the NI 1435 and the camera SerTC Serial transmission to the camera from the NI 1435 SerTFG Serial transmission to the NI 1435 from the camera CC 4...

Страница 9: ...the Medium configuration chip for Camera Link communication between the NI 1435 and the camera Z 3 0 Full configuration data and enable signals from the camera to the NI 1435 ZCLK Transmission clock o...

Страница 10: ...only line 3 Phase A Quadrature encoder Phase A positive connection for single ended or differential signals 4 Phase B Quadrature encoder Phase B negative connection for differential signals 5 NC No co...

Страница 11: ...ium Full Extended Full Camera connectors Two 26 pin SDR General purpose digital I O connectors One 15 pin high density female D Sub Host Bus Serial Control 26 Pin SDR Connector 26 Pin SDR Connector Fu...

Страница 12: ...inking Input voltage range 0 to 30 V Input ON voltage 3 5 to 30 V Input OFF voltage 0 to 2 V Turn on current 7 1 mA typical 14 mA maximum Maximum pulse rate 100 kHz Minimum pulse detected 10 s Reverse...

Страница 13: ...mperature 0 C to 55 C Tested in accordance with IEC 60068 2 1 and IEC 60068 2 2 Relative humidity range 10 to 90 noncondensing Tested in accordance with IEC 60068 2 56 Pollution Degree 2 Maximum altit...

Страница 14: ...cumentation CE Compliance This product meets the essential requirements of applicable European Directives as follows 2006 95 EC Low Voltage Directive safety 2004 108 EC Electromagnetic Compatibility D...

Страница 15: ...rograms tutorials technical presentations and a community area where you can share ideas questions and source code with developers around the world Additional Resources for LabVIEW Users Documentation...

Страница 16: ...visiting ni com certification If your product supports calibration you can obtain the calibration certificate for your product at ni com calibration National Instruments corporate headquarters is loca...

Страница 17: ...product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products technology refer to the appropriate location H...

Страница 18: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Отзывы: