Appendix A
Specifications
©
National Instruments Corporation
A-3
NI PXI-6682 User Manual
Output current ........................................ ±48 mA, max
Square wave rise/fall time
(10 to 90%) for 50
Ω
load..................... 0.5 ns min,
2.5 ns max
Input Characteristics
1
Frequency range ..................................... DC to 30 MHz
Input impedance ..................................... 1 k
Ω
, nominal
Input coupling ........................................ DC
Voltage level .......................................... 0 to +3.3 V, +5 V tolerant
Absolute maximum input voltage
2
......... –0.5 V to 6.0 V
Input threshold
Voltage threshold high.................... +2.3 V
Voltage threshold low ..................... +0.8 V
Asynchronous delay, t
pd
PFI <0..2> to
PXI_TRIG <0..7> output ................ 20 to 31 ns, typical
PFI <0..2> to
PXI_STAR <0..12> output ............. 10 ns, typical
Synchronized trigger
input setup time, t
setup
1
........................... 12 ns
Synchronized trigger
input hold time, t
hold
1
.............................. 0 ns
IRIG-B Input Characteristics (PFI0)
IRIG-B AM compatibility...................... IRIG-B 12X
Maximum Input voltage range .............. –5 V to +5 V
1
For PFI 0 these characteristics apply when the line is configured as a digital input. They do not apply when configured as an
IRIG-B AM input.
2
Stresses beyond those listed can cause permanent damage to the device. Exposure to absolute maximum rated conditions for
extended periods of time can affect device reliability. Functional operation of the device outside the conditions indicated in
the operational parts of the specifications is not implied.