NI NI-9853 Скачать руководство пользователя страница 13

EN 60079-0:2012, EN 60079-15:2010

IEC 60079-0: Ed 6, IEC 60079-15; Ed 4

UL 60079-0; Ed 5, UL 60079-15; Ed 3

CSA 60079-0:2011, CSA 60079-15:2012

Note

 For UL and other safety certifications, refer to the product label or

the 

Online Product Certification

 section.

Electromagnetic Compatibility

This product meets the requirements of the following EMC standards for sensitive

electrical equipment for measurement, control, and laboratory use:

EN 61326-2-1 (IEC 61326-2-1): Class A emissions; Industrial immunity

EN 55011 (CISPR 11): Group 1, Class A emissions

AS/NZS CISPR 11: Group 1, Class A emissions

FCC 47 CFR Part 15B: Class A emissions

ICES-001: Class A emissions

Note

 In the United States (per FCC 47 CFR), Class A equipment is intended

for use in commercial, light-industrial, and heavy-industrial locations. In

Europe, Canada, Australia and New Zealand (per CISPR 11) Class A

equipment is intended for use only in heavy-industrial locations.

Note

 Group 1 equipment (per CISPR 11) is any industrial, scientific, or

medical equipment that does not intentionally generate radio frequency

energy for the treatment of material or inspection/analysis purposes.

Note

 For EMC declarations and certifications, and additional information,

refer to the 

Online Product Certification

 section.

© National Instruments

13

NI-9853

Содержание NI-9853

Страница 1: ...NI 9853 2022 07 06...

Страница 2: ...rs 9 Cable Lengths 9 Number of CAN Nodes 9 NI 9853 Hardware Overview 9 NI 9853 Specifications 10 High Speed CAN Characteristics 10 Power Requirements 11 Physical Characteristics 11 Safety 11 Hazardous...

Страница 3: ...m Safety Guidelines Operate the NI 9853 only as described in this document Hot Surface This icon denotes that the component may be hot Touching this component may result in bodily injury Caution Do no...

Страница 4: ...n device between the CAN signals and the NI 9853 CAN pins The device must prevent the CAN Port to COM voltage from exceeding 55 V if there is a transient overvoltage condition Special Conditions for H...

Страница 5: ...duct is intended for use in industrial locations However harmful interference may occur in some installations when the product is connected to a peripheral device or test object or if the product is u...

Страница 6: ...connect the CAN bus signals Connect these signals using twisted pair cable Each port has two common pins COM that are internally connected to the module s isolated reference and serve as the referenc...

Страница 7: ...C 9 VSUP Table 2 Pin Assignments for CAN1 CAN Bus Topology and Termination A CAN bus consists of two or more CAN nodes cabled together The CAN_H and CAN_L pins of each node are connected to the main C...

Страница 8: ..._L Bus Cable Length Stub Length Connecting a CAN Bus to the NI 9853 You can connect each port of the NI 9853 to any location on a CAN bus Figure 2 shows one example of connecting CAN0 of the NI 9853 d...

Страница 9: ...ind detailed cable length recommendations in the ISO 11898 CiA DS 102 and DeviceNet specifications ISO 11898 specifies 40 m total cable length with a maximum stub length of 0 3 m for a bit rate of 1 M...

Страница 10: ...eed CAN transceiver that is fully compatible with the ISO 11898 standard and supports baud rates up to 1 Mbps Figure 4 NI 9853 Hardware Overview NI 9853 Specifications The following specifications are...

Страница 11: ...W max Thermal dissipation at 70 C Active mode 1 W max Sleep mode 250 mW max Physical Characteristics To clean the module wipe it with a dry towel Weight Approx 144 g 5 0 oz Safety Connect only voltage...

Страница 12: ...mited energy parts of equipment circuits powered by regulated low voltage sources and electronics Note Do not connect the NI 9853 to signals or use for measurements within Measurement Categories II II...

Страница 13: ...S NZS CISPR 11 Group 1 Class A emissions FCC 47 CFR Part 15B Class A emissions ICES 001 Class A emissions Note In the United States per FCC 47 CFR Class A equipment is intended for use in commercial l...

Страница 14: ...mber or product line and click the appropriate link in the Certification column Shock and Vibration To meet these specifications you must panel mount the system Operating vibration Random IEC 60068 2...

Страница 15: ...imize Our Environmental Impact web page at ni com environment This page contains the environmental regulations and directives with which NI complies as well as other environmental information not incl...

Страница 16: ...declaration of conformity This system affords the user protection for electromagnetic compatibility EMC and product safety You can obtain the DoC for your product by visiting ni com certification If y...